98%
921
2 minutes
20
Statement Of Problem: The demand to streamline workflow while increasing patient comfort and satisfaction in the manufacturing of removable complete dentures (CDs) is growing, and computer-aided design and computer-aided manufacturing (CAD-CAM) technology has gained prominence. However, a systematic review and meta-analysis of the clinical performance and patient-related outcome measures (PROMs) of digitally fabricated complete dentures is lacking.
Purpose: The purpose of this systematic review and meta-analysis was to determine whether digitally fabricated CDs improve the clinical performance and PROMs compared with conventionally fabricated CDs.
Material And Methods: This systematic review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses and was registered at the International Prospective Register of Systematic Reviews (CRD42023433909). This review aimed to address the question "Do digitally fabricated CDs improve clinical performance and PROMs compared with conventional CDs?" Two independent authors conducted electronic searches up to September 2023. Denture base retention and patient satisfaction were analyzed through the continuous outcome evaluated by mean difference and standard deviation, with 95% confidence intervals. The risk of bias in each study was assessed using the Risk of Bias In Non-randomized Studies of Interventions and the Risk of Bias based on the Cochrane risk of bias tool for randomized trials. The certainty of evidence was assessed using Grading of Recommendations, Assessment, Development and Evaluation.
Results: A total of 1505 articles were found during the search, and 16 were included in this review. The main outcomes were grouped into clinical performance (retention, adaptation or fit, clinician's denture quality assessment, masticatory efficiency, and occlusal force) and PROMs (patient satisfaction, oral health related quality of life, final choice, and willingness-to-pay). In terms of denture base retention, between conventional CDs and printed CDs analyses, conventional CDs exhibited better retention (P=.02), but no significant difference was found between the conventional CDs and milled CDs (P=.20). In terms of patient satisfaction, no statistically significant difference was found between the manufacturing methods of digitally fabricated CDs (printed CD, P=.55; milled CD, P=.08).
Conclusions: Digitally fabricated CDs showed similar or better clinical performance than conventional CDs, and different types of digital manufacturing processes for complete dentures did not influence PROMs.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.prosdent.2024.02.003 | DOI Listing |
J Adv Nurs
September 2025
Department of Internal Medicine, Erasmus MC, University Medical Center Rotterdam, Rotterdam, the Netherlands.
Aims: To assess self-reported practices and knowledge of nurses and prescribers (i.e., physicians and nurse practitioners) on intravenous fluid therapy, and to evaluate how this is documented through a clinical documentation review.
View Article and Find Full Text PDFJMIR Biomed Eng
August 2025
Cardiovascular Center and Divisions of Cardiology and Hospital Medicine, Department of Internal Medicine, National Taiwan University Hospital, No.7, Chung Shan S Rd, Taipei, 100225, Taiwan, 886 2-2312-3456.
Background: Photoplethysmography (PPG) signals captured by wearable devices can provide vascular age information and support pervasive and long-term monitoring of personal health condition.
Objective: In this study, we aimed to estimate brachial-ankle pulse wave velocity (baPWV) from wrist PPG and electrocardiography (ECG) from smartwatch.
Methods: A total of 914 wrist PPG and ECG sequences and 278 baPWV measurements were collected via the smartwatch from 80 men and 82 women with average age of 63.
Haematologica
September 2025
Department of Oncology, Sidney Kimmel Comprehensive Cancer Center, Johns Hopkins University School of Medicine, Baltimore, MD,.
Immunotherapies, including cell therapies, are effective anti-cancer agents. However, cellular product persistence can be limiting with short functional duration of activity contributing to disease relapse. A variety of manufacturing protocols are used to generate therapeutic engineered T-cells; these differ in techniques used for T-cell isolation, activation, genetic modification, and other methodology.
View Article and Find Full Text PDFCirc Cardiovasc Interv
September 2025
Keele Cardiovascular Research Group, Keele University, United Kingdom (M.A.M., R.B.).
Background: Evidence informing clinical guidelines assumes that all transcatheter aortic valve implantation (TAVI) devices have similar effectiveness, in other words, displaying a class effect across TAVI valves. We aimed to assess the comparative effectiveness of different TAVI platforms relative to other TAVI counterparts or surgical aortic valve replacement (SAVR).
Methods: MEDLINE/Embase/CENTRAL were searched from inception until April 2025, for randomized controlled trials comparing outcomes with different commercially available TAVI devices relative to other TAVI counterparts or SAVR.
Circ Arrhythm Electrophysiol
September 2025
Department of Congenital Heart Disease, Evelina London Children's Hospital, United Kingdom (S. Chivers, T.V., V.Z., S.M., G.M., W.R., E.R., D.F.A.L., T.G.D., O.I.M., G.K.S., J.M.S.).
Background: Fetal tachycardias can cause adverse fetal outcomes including ventricular dysfunction, hydrops, and fetal demise. Postnatally, ECG is the gold standard, but, in fetal practice, echocardiography is used most frequently to diagnose and monitor fetal arrhythmias. Noninvasive extraction of the fetal ECG (fECG) may provide additional information about the electrophysiological mechanism and monitoring of intermittent arrhythmias.
View Article and Find Full Text PDF