98%
921
2 minutes
20
Introduction: Loss of attention leads to less steady driving within the lane and is one of the main causes of road accidents. To improve road safety, vehicle-based parameters such as steering wheel angle and lateral position are used to objectively assess driving performance, especially in monotonous driving tasks.
Method: The present driving simulator study investigated the extent to which eight commonly used parameters are independent indicators of driving performance. Fifteen participants undertook a monotonous highway driving task for 1 h. Four steering angle parameters were examined: average steering angle (ASA), standard deviation of steering angle (SDSA), steering angle range (SAR), and steering reversal rate (SRR); as well as four lateral position parameters: mean lateral position (MLP), standard deviation of lateral position (SDLP), lateral position range (LPR), and the out-of-lane duration. Measurements were averaged across 2-minute epochs. Repeated measures correlation analysis evaluated the similarity between each parameter, and the variance inflation factor test evaluated the multicollinearity of all the parameters.
Results: The results demonstrated that some parameters are highly correlated and should not be used together to assess driving performance. It is recommended that the optimal combination is ASA and SAR to assess steering angle, and SDLP and out-of-lane to assess lateral position. Out-of-lane, as a factor directly contributing to road safety, is recommended because it has the least correlation with other parameters.
Practical Applications: If implemented, these recommendations may improve the assessment of driving performance in future studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jsr.2023.11.014 | DOI Listing |
Med Eng Phys
October 2025
Department of Engineering Science, University of Oxford, United Kingdom. Electronic address:
Traditionally, clinical devices are designed, tested and improved through lengthy and expensive laboratory experiments and clinical trials [1]. More recently, computational methods have allowed for rapid testing, speeding up the design process and enabling far more complete searches of design space. While computational models cannot fully capture the complexities of biological systems, they provide valuable insights into crucial underlying mechanisms, such as the effects of fluid-structure interactions (FSIs).
View Article and Find Full Text PDFOphthalmic Plast Reconstr Surg
September 2025
Department of Oculoplastic, Orbital & Lacrimal Surgery, Aichi Medical University Hospital. Nagakute, Aichi, Japan.
Purpose: To examine the position of the lower marginal arterial arcade (LMA) along the lower tarsal plate in microscopic specimens, particularly its relationship to anatomical landmarks.
Methods: Central sagittal sections of 27 lower eyelids (12 right, 10 left) from 15 Japanese cadavers (8 males, 7 females; aged 38-88 years, mean 70.5 years) were histologically examined.
Int J Surg Case Rep
September 2025
Pediatric Ophthalmology and Strabismus Division, King Khalid Eye Specialist Hospital, Riyadh, Saudi Arabia.
Introduction And Clinical Importance: To present a case of traumatic third cranial nerve palsy and discuss the management challenges associated with this condition.
Case Presentation: A 27-year-old male patient was referred to our hospital following a road traffic accident that resulted in multiple injuries, including traumatic brain injury, orbital injury. The patient presented with left complete upper lid ptosis, a fixed dilated pupil, and restricted extraocular muscle movements in the left eye except abduction with large exotropia >90 PD and hypotropia 25 PD diagnosed as left oculomotor nerve palsy.
Nat Sci Sleep
September 2025
Department of Otolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, People's Republic of China.
Aim: Obstructive sleep apnea (OSA) is characterized by repetitive upper airway collapse during sleep, resulting in frequent cortical arousals. However, currently used frequency-based arousal metrics do not sufficiently capture the heterogeneity and clinical significance of arousal responses. The odds ratio product (ORP) is a novel electroencephalographic marker that provides a continuous assessment of sleep depth and has the potential to serve as an objective measure of arousal intensity.
View Article and Find Full Text PDFJB JS Open Access
September 2025
Division of Orthopedic Surgery, Department of Regenerative and Transplant Medicine, Niigata University Graduate School of Medical and Dental Science, Niigata, Japan.
Background: Lower extremity alignment in knee osteoarthritis (OA) is conventionally assessed using standing radiographs. However, symptoms often manifest during gait. Understanding dynamic alignment during gait may help characterize disease progression and inform treatment strategies.
View Article and Find Full Text PDF