Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Introduction: Peritoneal dialysis (PD)-related peritonitis (PDRP) is a common cause of transfer to hemodialysis, patient morbidity, and is a risk factor for mortality. Associated patient anxiety can deter selection of PD for renal replacement therapy. Diagnosis relies on hospital laboratory tests; however, this might be achieved earlier if such information was available at the point-of-care (POC), thereby significantly improving outcomes. The presence of culturable microbes and the concentration of leukocytes in effluent both aid peritonitis diagnosis, as specified in the International Society for Peritoneal Dialysis (ISPD) diagnostic guidelines. Here, we report the development of 2 new methods providing such information in simple POC tests.
Methods: One approach uses a tetrazolium-based chemical reporting system, primarily focused on detecting bacterial contamination and associated vancomycin-sensitivity. The second approach uses a novel forward light-scatter device (QuickCheck) to provide an instant quantitative cell count directly from PD patient effluent.
Results: The tetrazolium approach detected and correctly distinguished laboratory isolates, taking 10 hours to provide non-quantitative results. We compared the technical performance of the light scatter leukocyte counting approach with spectrophotometry, hemocytometer counting and flow cytometry (Sysmex) using patient effluent samples. QuickCheck had high accuracy (94%) and was the most precise (coefficient of variation <4%), showing minimal bias, overall performing similarly to flow cytometry.
Conclusion: These complementary new approaches provide a simple means to obtain information to assist diagnosis at the POC. The first provides antibiotic sensitivity following 10 hours incubation, whereas the second optical approach (QuickCheck), provides instant accurate total leukocyte count.