A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

IMUs Can Estimate Hip and Knee Range of Motion during Walking Tasks but Are Not Sensitive to Changes in Load or Grade. | LitMetric

IMUs Can Estimate Hip and Knee Range of Motion during Walking Tasks but Are Not Sensitive to Changes in Load or Grade.

Sensors (Basel)

Biomechanics, Physical Performance and Exercise Research Group, Department of Health, Medicine and Human Sciences, Macquarie University's Biomechanics, Sydney, NSW 2113, Australia.

Published: March 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The ability to estimate lower-extremity mechanics in real-world scenarios may untether biomechanics research from a laboratory environment. This is particularly important for military populations where outdoor ruck marches over variable terrain and the addition of external load are cited as leading causes of musculoskeletal injury As such, this study aimed to examine (1) the validity of a minimal IMU sensor system for quantifying lower-extremity kinematics during treadmill walking and running compared with optical motion capture (OMC) and (2) the sensitivity of this IMU system to kinematic changes induced by load, grade, or a combination of the two. The IMU system was able to estimate hip and knee range of motion (ROM) with moderate accuracy during walking but not running. However, SPM analyses revealed IMU and OMC kinematic waveforms were significantly different at most gait phases. The IMU system was capable of detecting kinematic differences in knee kinematic waveforms that occur with added load but was not sensitive to changes in grade that influence lower-extremity kinematics when measured with OMC. While IMUs may be able to identify hip and knee ROM during gait, they are not suitable for replicating lab-level kinematic waveforms.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10934173PMC
http://dx.doi.org/10.3390/s24051675DOI Listing

Publication Analysis

Top Keywords

hip knee
12
imu system
12
kinematic waveforms
12
estimate hip
8
knee range
8
range motion
8
sensitive changes
8
load grade
8
lower-extremity kinematics
8
walking running
8

Similar Publications