Glucosinolates (GLSs) are a well-studied sulfur-containing compound found in plants that play critical roles in plant resistance and human health. Correctly identifying and reliably quantifying the total and individual GLS content is of great importance. An improved method as an alternative to the ISO 9167-1 (ISO) method is developed in the present study. An efficient extraction and purification procedure is proposed with a commercially available dimethylaminopropyl (DEA)-based weak anion exchange solid-phase extraction (SPE) cartridge instead of using the self-prepared ion-exchange columns in the ISO method. The GLSs are identified and quantified by ultra high-performance liquid chromatography (UHPLC) high-resolution mass spectrometry (HRMS). The method demonstrates a comparable quantification of total and individual GLSs on certified rapeseeds and other vegetables when compared to the ISO method. The developed SPE method is simpler and more efficient, thus allowing for applications to a large sample size with reduced analysis time, improved repeatability and accuracy, and possible automation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10931338 | PMC |
http://dx.doi.org/10.3390/foods13050650 | DOI Listing |
Blood Press Monit
September 2025
Hypertension Center STRIDE-7, National and Kapodistrian University of Athens, School of Medicine, Third Department of Medicine, Sotiria Hospital, Athens, Greece.
Objective: To evaluate the accuracy of the automated oscillometric upper-arm cuff blood pressure (BP) monitor Microlife BP3KV1-5X (BP B6 Connect) for home use in a general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018) and its amendments (1:2020 and 2:2024).
Methods: Participants were recruited to fulfill the age, sex, BP, and arm distribution criteria of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) and its amendments (1:2020 and 2:2024) in a general population using the same arm sequential measurement method. A single wide-range cuff of the test device was used for arm circumference 22-42 cm.
Sci Justice
September 2025
Department of Analytical, Environmental and Forensic Sciences, King's College London, London, UK.
ISO 21043 is a new international standard for forensic science. It provides requirements and recommendations designed to ensure the quality of the forensic process. It includes Parts on: 1 vocabulary; 2 recovery, transport, and storage of items; 3 analysis; 4 interpretation; and 5 reporting.
View Article and Find Full Text PDFMed Phys
September 2025
Division of Medical Radiation Physics and Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland.
Background: Radiotherapy workflows conventionally deliver one treatment plan multiple times throughout the treatment course. Non-coplanar techniques with beam angle optimization or dosimetrically optimized pathfinding (DOP) exploit additional degrees of freedom to improve spatial conformality of the dose distribution compared to widely used techniques like volumetric-modulated arc therapy (VMAT). The temporal dimension of dose delivery can be exploited using multiple plans (sub-plans) within one treatment course.
View Article and Find Full Text PDFAnal Methods
September 2025
Institut de recherche Robert-Sauvé en santé et en sécurité du travail (IRSST), Qc, Canada.
Toluene diisocyanate (TDI) is an irritant (skin, eye and respiratory) and a sensitizer. This compound is used to manufacture polyurethane materials such as flexible foams. The use of isocyanates may lead to exposure by inhalation and/or skin contact and isocyanates are recognized as a cause of occupational asthma.
View Article and Find Full Text PDFJ Perinatol
September 2025
Department of Pediatrics, Asan Medical Center Children's Hospital, University of Ulsan College of Medicine, Seoul, Korea.
Objective: To quantify agreement between oscillometric non-invasive blood pressure (NIBP) and invasive arterial blood pressure (IBP) in infants <500 g during the first postnatal week.
Study Design: Retrospective cohort of infants with a birth weight <500 g admitted to a tertiary NICU (2011-2023). Paired IBP-NIBP readings obtained within 1 min were analyzed.