A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Added value of a connected glucose meter for glycorrhachia assessment. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objectives: The aim of this study was to demonstrate the performance and added value of rapid glucose determination in cerebrospinal fluid using a connected glucometer.

Design And Methods: Intra-assay and inter-assay accuracies were calculated using residual clinical samples. Accuracies were measured by comparing the results obtained with the glucometer to those from the central laboratory on a large routine chemistry platform.

Results: The intra-assay coefficients of variation were between 6.1% and 6.2% for low values (18 mg/dL) and between 5.6% and 6.8% for high values (58 mg/dL). The inter-assay coefficients of variation were between 9.4% and 16.3% for the low values (18 mg/dL) and between 5.7% and 8.7% for the high values (pool; ±75 mg/dL). The regression equation by comparison to the central laboratory was y = 4.08 + 0.82 x, with a coefficient of determination (r) of 0.95.

Conclusions: The measurement of glycorrhachia with a connected glucometer before the analysis in the central laboratory allows a rapid orientation in the deferential diagnosis of a meningitis of viral vs bacterial origin. The response time is fast (6 s) and requires only a small amount of fluid (1.2 μL), which is important in infants, especially since lumbar puncture is an integral part of the investigation of the origin of a fever in this population.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10924199PMC
http://dx.doi.org/10.1016/j.plabm.2024.e00384DOI Listing

Publication Analysis

Top Keywords

central laboratory
12
coefficients variation
8
low values
8
values 18 mg/dl
8
high values
8
connected glucose
4
glucose meter
4
meter glycorrhachia
4
glycorrhachia assessment
4
assessment objectives
4

Similar Publications