A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Full-Length Single Protein Molecules Tracking and Counting in Thin Silicon Channels. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Emerging single-molecule protein sensing techniques are ushering in a transformative era in biomedical research. Nevertheless, challenges persist in realizing ultra-fast full-length protein sensing, including loss of molecular integrity due to protein fragmentation, biases introduced by antibodies affinity, identification of proteoforms, and low throughputs. Here, a single-molecule method for parallel protein separation and tracking is introduced, yielding multi-dimensional molecular properties used for their identification. Proteins are tagged by chemo-selective dual amino-acid specific labels and are electrophoretically separated by their mass/charge in custom-designed thin silicon channel with subwavelength height. This approach allows analysis of thousands of individual proteins within a few minutes by tracking their motion during the migration. The power of the method is demonstrated by quantifying a cytokine panel for host-response discrimination between viral and bacterial infections. Moreover, it is shown that two clinically-relevant splice isoforms of Vascular endothelial growth factor (VEGF) can be accurately quantified from human serum samples. Being non-destructive and compatible with full-length intact proteins, this method opens up ways for antibody-free single-protein molecule quantification.

Download full-text PDF

Source
http://dx.doi.org/10.1002/adma.202314319DOI Listing

Publication Analysis

Top Keywords

thin silicon
8
protein sensing
8
protein
5
full-length single
4
single protein
4
protein molecules
4
molecules tracking
4
tracking counting
4
counting thin
4
silicon channels
4

Similar Publications