A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Evaluation of a new portable corneal topography system for self-measurement using smartphones: a pilot study. | LitMetric

Evaluation of a new portable corneal topography system for self-measurement using smartphones: a pilot study.

Graefes Arch Clin Exp Ophthalmol

Department of System Design Engineering, Faculty of Science and Technology, Keio University, Kanagawa, Tokyo, Japan.

Published: July 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Herein, we propose the use of the "KeraVio Ring", which is a portable, selfie-based, smartphone-attached corneal topography system that is based on the Placido ring videokeratoscope. The goal of this study was to evaluate and compare corneal parameters between KeraVio Ring and conventional corneal tomography images.

Methods: We designed the KeraVio Ring as a device comprising 3D-printed LED rings for generating Placido rings that can be attached to a smartphone. Two LED rings are attached to a cone-shaped device, and both corneas are illuminated. Selfies were taken using the KeraVio Ring attached to the smartphone without assistance from any of the examiners. Captured Placido rings on the cornea were analysed by intelligent software to calculate corneal parameters. Patients with normal, keratoconus, or LASIK-treated eyes were included. Anterior segment optical coherence tomography (AS-OCT) was also performed for each subject.

Results: We found highly significant correlations between the steepest and flattest keratometry, corneal astigmatism, and vector components obtained with the KeraVio Ring and AS-OCT. In subjects with normal, keratoconus, and LASIK-treated eyes, the mean difference in corneal astigmatism between the two devices was -0.8 ± 1.4 diopters (D) (95% limits of agreement (LoA), -3.6 to 2.0), -1.8 ± 3.7 D (95% LoA, -9.1 to 5.5), and -1.5 ± 1.3 D (95% LoA, -4.0 to 1.1), respectively.

Conclusions: The experimental results showed that the corneal parameters obtained by the KeraVio Ring were correlated with those obtained with AS-OCT. The KeraVio Ring has the potential to address an unmet need by providing a tool for portable selfie-based corneal topography.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00417-024-06426-9DOI Listing

Publication Analysis

Top Keywords

keravio ring
24
corneal topography
12
corneal parameters
12
corneal
9
topography system
8
portable selfie-based
8
parameters keravio
8
led rings
8
placido rings
8
rings attached
8

Similar Publications