Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Although the enormous potential of droplet-based microfluidics has been successfully demonstrated in the past two decades for medical, pharmaceutical, and academic applications, its inherent potential has not been fully exploited until now. Nevertheless, the cultivation of biological cells and 3D cell structures like spheroids and organoids, located in serially arranged droplets in micro-channels, has a range of benefits compared to established cultivation techniques based on, e.g., microplates and microchips. To exploit the enormous potential of the droplet-based cell cultivation technique, a number of basic functions have to be fulfilled. In this paper, we describe microfluidic modules to realize the following basic functions with high precision: (i) droplet generation, (ii) mixing of cell suspensions and cell culture media in the droplets, (iii) droplet content detection, and (iv) active fluid injection into serially arranged droplets. The robustness of the functionality of the Two-Fluid Probe is further investigated regarding its droplet generation using different flow rates. Advantages and disadvantages in comparison to chip-based solutions are discussed. New chip-based modules like the gradient, the piezo valve-based conditioning, the analysis, and the microscopy module are characterized in detail and their high-precision functionalities are demonstrated. These microfluidic modules are micro-machined, and as the surfaces of their micro-channels are plasma-treated, we are able to perform cell cultivation experiments using any kind of cell culture media, but without needing to use surfactants. This is even more considerable when droplets are used to investigate cell cultures like stem cells or cancer cells as cell suspensions, as 3D cell structures, or as tissue fragments over days or even weeks for versatile applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10891953PMC
http://dx.doi.org/10.3390/mi15020250DOI Listing

Publication Analysis

Top Keywords

microfluidic modules
12
cell
9
enormous potential
8
potential droplet-based
8
cells cell
8
cell structures
8
serially arranged
8
arranged droplets
8
cell cultivation
8
basic functions
8

Similar Publications

Epidermal growth factor receptor (EGFR) mutation detection is now commonly used in the management of cancer patients, particularly those diagnosed with non-small cell lung cancer. Molecular beacon-based sensing is direct and rapid, but its sensitivity is low. Conversely, high-sensitivity detection methodologies based on amplification are robust and sensitive but are limited by relatively require long turnaround times.

View Article and Find Full Text PDF

Although cold atmospheric plasma (CAP) has shown promise in facilitating wound repair due to its non-thermal and non-invasive properties, its dynamic effects on cellular response and metabolic regulation remain poorly characterized, and the mechanism is still unclear. In this study, we developed a microfluidic experimental system that integrates a CAP treatment module with multiparametric in situ sensing capabilities, along with precise environmental control of temperature, humidity, and CO concentration. A stratified microfluidic chip was engineered to co-culture HaCaT keratinocytes and HSF fibroblasts.

View Article and Find Full Text PDF

Microfluidic platforms offer a powerful approach for ultimately replicating vascularization , enabling precise microscale control and manipulation of physical parameters. Despite these advances, the real-time ability to monitor and quantify mechanical forces-particularly pressure-within microfluidic environments remains constrained by limitations in cost and compatibility across diverse device architectures. Our work presents an advanced experimental module for quantifying pressure within a vascularizing microfluidic platform.

View Article and Find Full Text PDF

A wearable multi-parameter electrochemical detection and signal processing system for real-time sweat analysis.

Mikrochim Acta

August 2025

School of Mechanical Engineering, Beijing Institute of Technology, 5 South Zhongguancun Street, Haidian District, Beijing, 100081, China.

This study presents a wearable multi-parameter electrochemical detection system (WMEDS) designed for the simultaneous monitoring of sweat biomarkers. The system integrates a microcontroller, a dual-mode signal acquisition circuit, and a low-power Bluetooth module. To address the non-stationary electrochemical signals, a preprocessing approach combining Savitzky-Golay filtering with Z-score-difference detection is employed.

View Article and Find Full Text PDF

Wearable and implantable microfluidic technologies for future digital therapeutics.

Lab Chip

September 2025

Department of Materials Science and Engineering, Yonsei University, Seoul 03722, Republic of Korea.

Microfluidic technology, originally developed for lab-on-a-chip applications, has rapidly expanded into wearable and implantable biomedical systems, enabling precise fluid handling for real-time biosensing, targeted drug delivery, and closed-loop therapeutics. This review provides a comprehensive overview of recent advancements in microfluidic platforms designed for integration with the human body, focusing on both wearable devices and implantable systems. Key design strategies are highlighted, including the integration of microfluidics with soft electronics, wireless communication, and multimodal sensing to enhance mechanical adaptability and functional versatility in dynamic biological environments.

View Article and Find Full Text PDF