A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Comparison of UESCOPE VL 400, I-View, Non-Channeled Airtraq Videolaryngoscopes and Macintosh Laryngoscope for Tracheal Intubation in Simulated Out-of-Hospital Conditions: A Randomized Crossover Manikin Study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The aim of the study was to test the hypothesis that the results obtained with three different types of video laryngoscopes (UESCOPE VL-400, I-View, Non-Channeled Aitraq) with and without an endotracheal stylet should be better than the results obtained with a Macintosh laryngoscope in a simulated out-of-hospital scenario by a person without clinical experience. Primary outcome measures were the time taken to successfully achieve tracheal intubation (TI). Secondary outcomes included the grade of glottic view (Cormack and Lehane grades 1-4), the incidence of successful TI, the number of audible dental clicks indicating potential dental damage, the level of effort required to perform TI, and the operator's comfort during the procedure. The time required to achieve tracheal intubation successfully was significantly longer with the Macintosh laryngoscope and Airtraq than with the other video laryngoscopes. The use of the stylet significantly reduced the time required for tracheal intubation with the Macintosh laryngoscope (21.8 sec. vs. 24.0 sec., = 0.026), UESCOPE VL 400 (18.1 sec. vs. 23.4 sec., = 0.013), and Airtraq (22.7 sec. vs. 34.5 sec., < 0.001). There were no significant differences in intubation time when using the I-View with or without stylets. No differences were observed in the Cormack-Lehane grading. The success rate of intubation was 100% for the Macintosh and I-View laryngoscopes used with or without stylets and for the UESCOPE VL 400 and Airtraq laryngoscopes used with stylets. Without stylets, the success rate of intubation was 96.6% for the UESCOPE VL 400 and 86.6% for the Airtraq. There were no significant differences in the risk of dental damage between the Macintosh, UESCOPE VL 400, I-View, and Airtraq laryngoscopes, regardless of the use of stylets (without and with stylets). The use of stylets significantly reduced dental damage only for the Airtraq laryngoscope: 8 (26.6%) vs. 2 (6.6%). Statistically significant differences in perceived exertion were observed between the mentioned laryngoscopes, both with and without stylets. However, there were no differences in the comfort of use between the laryngoscopes, regardless of the use of stylets (without and with stylets. The use of stylets led to better comfort in the case of the Macintosh (2.5 vs. 3, = 0.043) and UESCOPE VL 400 (2 vs. 3, = 0.008) laryngoscopes. In our study, the I-View and UESCOPE VL-400 video laryngoscopes provided better intubation results than the Macintosh laryngoscope in terms of time needed to intubate, glottis visibility, and reduction in dental damage. The use of the stylet did not significantly improve the intubation results compared to the results obtained in direct laryngoscopy. Due to the small study group and the manikin model, additional studies should be performed on a larger study group.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10887893PMC
http://dx.doi.org/10.3390/healthcare12040452DOI Listing

Publication Analysis

Top Keywords

uescope 400
24
macintosh laryngoscope
20
laryngoscopes stylets
20
stylets stylets
20
tracheal intubation
16
dental damage
16
video laryngoscopes
12
stylets
11
intubation
9
laryngoscopes
9

Similar Publications