Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The MiniMed™ 780G system (MM780G) with Guardian™ 4 sensor includes a 100 mg/dL glucose target (GT) and automated insulin corrections up to every 5 min and was recently approved for use in the United States. In the present study, early real-world MM780G performance and the use of recommended system settings (100 mg/dL GT with an active insulin time of 2 h), by individuals with type 1 diabetes, were evaluated. CareLink™ personal data uploaded between the launch of the MM780G to August 22, 2023 were aggregated and underwent retrospective analysis (based on user consent) and if users had ≥10 days of continuous glucose monitoring (CGM) data. The 24-h day CGM metrics, including mean glucose, percentage of time spent in (%TIR), above (%TAR), and below (%TBR) target range (70-180 mg/dL), in addition to delivered insulin and closed-loop (CL) exits, were compared between an overall group ( = 7499) and individuals who used recommended settings (each, for >95% of the time). An analysis of the same metrics for MiniMed™ 770G system (MM770G) users ( = 3851) who upgraded to the MM780G was also conducted (paired -test or Wilcoxon signed-rank test,  < 0.05 considered statistically significant). For MM780G users, CGM use, and time in CL were >90% and all MM780G CGM metrics exceeded consensus-recommended goals. With recommended settings (22% of all users), mean %TIR and %TITR (70-140 mg/dL) were 81.4% and 56.4%, respectively. For individuals who upgraded from the MM770G, %TIR and %TITR increased from 73.2% to 78.3% and 45.8% to 52.6%, respectively, while %TAR reduced from 25.1% to 20.2% ( < 0.001, for all three). CL exits/week averaged <1, for all MM780G users. Early real-world MM780G use in the United States demonstrated a high percentage of time in range with low time above and below range. These outcomes are similar to those observed for real-world MM780G use in other countries.

Download full-text PDF

Source
http://dx.doi.org/10.1089/dia.2023.0453DOI Listing

Publication Analysis

Top Keywords

recommended settings
12
early real-world
8
minimed™ 780g
8
united states
8
cgm metrics
8
%tir %titr
8
mm780g
5
real-world performance
4
performance minimed™
4
780g advanced
4

Similar Publications

Background: Assisted vaginal birth is a lifesaving procedure where health workers use special devices to expedite birth vaginally when some complications emerge, such as due to prolonged labor. When the use of assisted vaginal birth is possible and appropriate, it provides benefits over cesarean section. These benefits include shorter recovery, reduced hospital stays, lower risks of complications, cost savings, and greater likelihood of vaginal birth in future pregnancies.

View Article and Find Full Text PDF

Importance: Adolescents account for almost half of the 2.5 million diagnosed sexually transmitted infections in the US annually, and the emergency department functions as the primary source of health care for many adolescents. No recommendations exist for emergency department gonorrhea and chlamydia screening.

View Article and Find Full Text PDF

Importance: Black individuals have a twofold higher rate of prostate cancer death in the US compared with the average population with prostate cancer. Few guidelines support race-conscious screening practices among at-risk Black individuals.

Objective: To examine structural factors that facilitate or impede access to prostate cancer screening among Black individuals in the US.

View Article and Find Full Text PDF

Artificial intelligence (AI) is increasingly applied in nutrition science to support clinical decision-making, prevent diet-related diseases such as obesity and type 2 diabetes, and improve nutrition care in both preventive and therapeutic settings. By analyzing diverse datasets, AI systems can support highly individualized nutritional guidance. We focus on machine learning applications and image recognition tools for dietary assessment and meal planning, highlighting their potential to enhance patient engagement and adherence through mobile apps and real-time feedback.

View Article and Find Full Text PDF

Removal and inactivation of human coronavirus surrogates from hard and soft surfaces using disinfectant wipes.

Appl Environ Microbiol

September 2025

Department of Food, Nutrition, and Packaging Sciences, Clemson University, Clemson, South Carolina, USA.

Disinfectant wipes are widely used to reduce microbial contamination on surfaces, yet there is limited information on how viruses are physically removed or chemically inactivated during wiping. This study aimed to address this gap by comparing the contributions of physical removal and chemical inactivation to overall disinfection efficacy. Glass and vinyl coupons were contaminated with SARS-CoV-2 surrogates, bovine coronavirus (BCoV), or human coronavirus OC43, at an initial titer of 5-6 log TCID/surface with 5% soil load.

View Article and Find Full Text PDF