Article Abstract

Purpose: To evaluate the clinical and radiographic outcomes of patients who have undergone bioabsorbable screw fixation for intact, stable grade I and II osteochondritis dissecans (OCD) lesions for which at least 6 months of conservative management has failed.

Methods: A retrospective review of prospectively collected data from a single institution was performed to identify patients who underwent internal fixation of stable grade I and II OCD lesions (according to the Guhl classification) between January 2010 and January 2020. Patients were included regardless of the presence of concomitant procedures. The inclusion criteria consisted of (1) primary surgery, (2) failure of at least 6 months of conservative management, (3) the use of a bioabsorbable screw (or screws), and (4) minimum 2-year clinical follow-up. Radiographs were obtained at a minimum of 1 year postoperatively. Patient demographic characteristics, clinical patient-reported outcomes, complications, and failure rates were noted.

Results: Twenty-four knees among 23 patients (96% follow-up) were analyzed and followed up for 6.36 ± 3.42 years (range, 2.0-12.7 years). Patients showed statistically significant postoperative improvements in all patient-reported outcomes including the Lysholm score, International Knee Documentation Committee score, and Knee Injury and Osteoarthritis Outcome Score subscales ( < .05). In 3 knees (12%), a reoperation was required due to failure at an average of 3.64 years after the index procedure. No specific complications were attributed to the use of bioabsorbable screws. Patients in whom primary surgical treatment failed did not differ in demographic characteristics, arthroscopic findings, or surgical treatment from those who had successful treatment.

Conclusions: Internal fixation of stable grade I and II OCD lesions with bioabsorbable screws produces reliable results with a 12% rate of failure in appropriately indicated patients in whom at least 6 months of conservative management has failed. Clinical outcomes improved significantly during the mid-term follow-up period.

Level Of Evidence: Level IV, therapeutic case series.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10867764PMC
http://dx.doi.org/10.1016/j.asmr.2023.100863DOI Listing

Publication Analysis

Top Keywords

bioabsorbable screw
12
stable grade
12
ocd lesions
12
months conservative
12
conservative management
12
screw fixation
8
failure rates
8
mid-term follow-up
8
osteochondritis dissecans
8
internal fixation
8

Similar Publications

Medial meniscus posterior root tears (MMPRTs) are a risk factor for knee osteoarthritis because of the destruction of the meniscal hoop structure. Medial open wedge high tibial osteotomy can be combined with MMPRT pullout repair to reduce pressure on the medial compartment. However, when these techniques are performed simultaneously, the locking screws of the plate interfere with the tibial bone tunnel, resulting in suture damage or nonanatomic MMPRT repair.

View Article and Find Full Text PDF

Background: Bioabsorbable interference screws are a widely used option for graft fixation in anterior cruciate ligament (ACL) reconstruction. Their ability to degrade over time and avoid secondary hardware removal makes them advantageous. However, complications such as breakage and intra-articular migration of screws can cause significant clinical issues, including joint pain, swelling, and cartilage damage.

View Article and Find Full Text PDF

Bioabsorbable polymer stents (BPSs) were developed to address the long-term clinical drawbacks associated with permanent metallic stents by gradually dissolving over time before these drawbacks have time to develop. However, the polymers used in BPSs, such as polylactic acid (PLA), have lower mechanical properties than metals, often requiring larger struts to provide the necessary structural support. These larger struts have been linked to delayed endothelialisation and an increased risk of stent thrombosis.

View Article and Find Full Text PDF

Background: No study has reported on the use of bioabsorbable screws in modified Mitchell osteotomies. This study aimed to clarify the clinical and radiographic findings of modified Mitchell osteotomy using a bioabsorbable screw compared with the use of a titanium screw.

Methods: Fifty-one feet from 43 patients with hallux valgus angles (HVAs) > 20° and <40° were included in the study.

View Article and Find Full Text PDF

Background: This study aimed to compare clinical outcomes and tibial tunnel widening following anterior cruciate ligament reconstruction (ACLR) using allo-tibialis tendon performed with an all-inside technique (All-inside group) or an aperture fixation technique with a bioabsorbable screw (Aperture fixation group) for tibial side fixation.

Methods: A retrospective analysis of 36 patients between 2012 and 2022 was conducted. Patients who received a single-bundle anatomical ACLR with allo-tibialis tendon using suspensory femoral fixation were divided into two groups according to tibial fixation methods: adjustable suspensory fixative device or aperture fixation technique with a bioabsorbable screw.

View Article and Find Full Text PDF