Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Background: Previously, ablation at the outflow tract was considered to be safe and rarely affected the His-Purkinje system due to their spatial distance. However, we have reported a case of right bundle branch block (RBBB) and junctional beats that were recorded during radiofrequency catheter ablation in a patient who had a history of peri-membranous ventricular septal defect (pmVSD) closure and the implantation of a metallic occluder.
Case Summary: A 16-year-old girl with a metallic occluder for peri-membranous ventricular septum defect underwent an ablation procedure for premature ventricular complexes. During the ablation at the right ventricular outflow tract (RVOT), RBBB and junctional beats were recorded. His bundle potentials and the high-frequency potential generated by electrical interference were observed when mapping the margin of the occluder. To ensure safety, we attempted ablation at the right coronary cusp in the left ventricular outflow tract, which eventually proved to be successful, presenting an alternative ablation strategy.
Conclusion: This is a rare report of RBBB and junctional beats observed during ablation at RVOT in a patient with pmVSD and a metallic occluder. The observed damage to the His-Purkinje system may be attributed to uncontrolled radiofrequency energy heating up caused by the metallic device. This case emphasizes the importance of thorough electroanatomic and activation mapping prior to starting the ablation procedure, especially in complicated cases. Furthermore, it suggests that ablation at a relatively remote position is both feasible and relatively safe for patients with occluder devices.