A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Clinical Super-Resolution Computed Tomography of Bone Microstructure: Application in Musculoskeletal and Dental Imaging. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Clinical cone-beam computed tomography (CBCT) devices are limited to imaging features of half a millimeter in size and cannot quantify the tissue microstructure. We demonstrate a robust deep-learning method for enhancing clinical CT images, only requiring a limited set of easy-to-acquire training data.

Methods: Knee tissue from five cadavers and six total knee replacement patients, and 14 teeth from eight patients were scanned using laboratory CT as training data for the developed super-resolution (SR) technique. The method was benchmarked against ex vivo test set, 52 osteochondral samples are imaged with clinical and laboratory CT. A quality assurance phantom was imaged with clinical CT to quantify the technical image quality. To visually assess the clinical image quality, musculoskeletal and maxillofacial CBCT studies were enhanced with SR and contrasted to interpolated images. A dental radiologist and surgeon reviewed the maxillofacial images.

Results: The SR models predicted the bone morphological parameters on the ex vivo test set more accurately than conventional image processing. The phantom analysis confirmed higher spatial resolution on the SR images than interpolation, but image grayscales were modified. Musculoskeletal and maxillofacial CBCT images showed more details on SR than interpolation; however, artifacts were observed near the crown of the teeth. The readers assessed mediocre overall scores for both SR and interpolation. The source code and pretrained networks are publicly available.

Conclusion: Model training with laboratory modalities could push the resolution limit beyond state-of-the-art clinical musculoskeletal and dental CBCT. A larger maxillofacial training dataset is recommended for dental applications.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10995025PMC
http://dx.doi.org/10.1007/s10439-024-03450-yDOI Listing

Publication Analysis

Top Keywords

computed tomography
8
musculoskeletal dental
8
vivo test
8
test set
8
imaged clinical
8
image quality
8
musculoskeletal maxillofacial
8
maxillofacial cbct
8
clinical
7
clinical super-resolution
4

Similar Publications