A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Multivariate optimization for extraction of 2-methylimidazole and 4-methylimidazole from açaí-based food products using polymeric ionic liquid-based sorbent coatings in solid-phase microextraction coupled to gas chromatography-mass spectrometry. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

In this study, polymeric ionic liquids featuring different functional moieties were applied as sorbent coatings in direct-immersion solid-phase microextraction (DI-SPME) for the extraction of 2-methylimidazole (2-MI) and 4-methylimidazole (4-MI) from açaí-based food products followed by gas chromatography-mass spectrometry (GC-MS) analysis. The analytical method was optimized using a sequential experimental design. Variables used in GC-MS such as desorption time, as well as for SPME-DI, including extraction time, extraction temperature, incubation time of extraction, amount of NaCl in the extract, and stirring rate, were optimized. The fitness-for-purpose of the method was verified by the linearity of matrix-matched calibration curves (R ≥ 0.9921), adequate recoveries (81.7-89.7 %), and precision (relative standard deviations ≤11.2 %). The method was applied to twenty-five samples of açaí-based food products. 4-MI was found in four samples whereas 2-MI was not detected above the limit of detection. The method was found to be suitable for quality control analysis.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2024.138593DOI Listing

Publication Analysis

Top Keywords

açaí-based food
12
food products
12
extraction 2-methylimidazole
8
polymeric ionic
8
sorbent coatings
8
solid-phase microextraction
8
gas chromatography-mass
8
chromatography-mass spectrometry
8
time extraction
8
extraction
5

Similar Publications