98%
921
2 minutes
20
Objective: Instrumented mouthguard (iMG) systems use different signal processing approaches limiting field-based inter-study comparisons, especially when artefacts are present in the signal. The objective of this study was to assess the frequency content and characteristics of head kinematic signals from head impact reconstruction laboratory and field-based environments to develop an artefact attenuation filtering method (HEADSport filter method).
Methods: Laboratory impacts (n=72) on a test-dummy headform ranging from 25 to 150 g were conducted and 126 rugby union players were equipped with iMGs for 209 player-matches. Power spectral density (PSD) characteristics of the laboratory impacts and on-field head acceleration events (HAEs) (n=5694) such as the 95th percentile cumulative sum PSD frequency were used to develop the HEADSport method. The HEADSport filter method was compared with two other common filtering approaches (Butterworth-200Hz and CFC180 filter) through signal-to-noise ratio (SNR) and mixed linear effects models for laboratory and on-field events, respectively.
Results: The HEADSport filter method produced marginally higher SNR than the Butterworth-200Hz and CFC180 filter and on-field peak linear acceleration (PLA) and peak angular acceleration (PAA) values within the magnitude range tested in the laboratory. Median PLA and PAA (and outlier values) were higher for the CFC180 filter than the Butterworth-200Hz and HEADSport filter method (p<0.01).
Conclusion: The HEADSport filter method could enable iMG field-based inter-study comparisons and is openly available at https://github.com/GTBiomech/HEADSport-Filter-Method.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10831454 | PMC |
http://dx.doi.org/10.1136/bmjsem-2023-001758 | DOI Listing |
Ann Biomed Eng
May 2025
Virginia Tech (Biomedical Engineering and Mechanics), Blacksburg, VA, USA.
Instrumented head acceleration measurement devices are commonly used in research studies to determine head acceleration exposure in certain populations. Instrumented mouthguards pair directly to the user's teeth and offer six-degree-of-freedom measurements. Though many studies have recently used these devices, post-processing techniques vary by study.
View Article and Find Full Text PDFIEEE Trans Biomed Eng
September 2024
Objective: Impact kinematics are widely employed to investigate mechanisms of traumatic brain injury (TBI). However, they are susceptible to noise and artefacts; thus, require data filtering. Few studies have focused on how data filtering affects brain strain most relevant to TBI.
View Article and Find Full Text PDFBMJ Open Sport Exerc Med
January 2024
Nanotechnology and Integrated Bioengineering Centre (NIBEC), Ulster University, Belfast, UK.
Objective: Instrumented mouthguard (iMG) systems use different signal processing approaches limiting field-based inter-study comparisons, especially when artefacts are present in the signal. The objective of this study was to assess the frequency content and characteristics of head kinematic signals from head impact reconstruction laboratory and field-based environments to develop an artefact attenuation filtering method (HEADSport filter method).
Methods: Laboratory impacts (n=72) on a test-dummy headform ranging from 25 to 150 g were conducted and 126 rugby union players were equipped with iMGs for 209 player-matches.