A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Luminescence thermometry driven by a support vector machine: a strategy toward precise thermal sensing. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Luminescence thermometry is a promising non-contact temperature measurement technique, but improving the precision and reliability of this method remains a challenge. Herein, we propose a thermal sensing strategy based on a machine learning. By using GdGaO: Er-Yb as the sensing medium, a support vector machine (SVM) is preliminarily adopted to establish the relationship between temperature and upconversion emission spectra, and the sensing properties are discussed through the comparison with luminescence intensity ratio (LIR) and multiple linear regression (MLR) methods. Within a wide operating temperature range (303-853 K), the maximum and the mean measurement errors actualized by the SVM are just about 0.38 and 0.12 K, respectively, much better than the other two methods (3.75 and 1.37 K for LIR and 1.82 and 0.43 K for MLR). Besides, the luminescence thermometry driven by the SVM presents a high robustness, although the spectral profiles are distorted by the interferences within the testing environment, where, however, LIR and MLR approaches become ineffective. Results demonstrate that the SVM would be a powerful tool to be applied on the luminescence thermometry for achieving a high sensing performance.

Download full-text PDF

Source
http://dx.doi.org/10.1364/OL.507901DOI Listing

Publication Analysis

Top Keywords

luminescence thermometry
16
thermometry driven
8
support vector
8
vector machine
8
thermal sensing
8
luminescence
5
sensing
5
driven support
4
machine strategy
4
strategy precise
4

Similar Publications