A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Myelography Using Energy-Integrating Detector CT Versus Photon-Counting Detector CT for Detection of CSF-Venous Fistulas in Patients With Spontaneous Intracranial Hypotension. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

CSF-venous fistulas (CVFs), which are an increasingly recognized cause of spontaneous intracranial hypotension (SIH), are often diminutive in size and exceedingly difficult to detect by conventional imaging. This purpose of this study was to compare energy-integrating detector (EID) CT myelography and photon-counting detector (PCD) CT myelography in terms of image quality and diagnostic performance for detecting CVFs in patients with SIH. This retrospective study included 38 patients (15 men and 23 women; mean age, 55 ± 10 [SD] years) with SIH who underwent both clinically indicated EID CT myelography (slice thickness, 0.625 mm) and PCD CT myelography (slice thickness, 0.2 mm; performed in ultrahigh-resolution mode) to assess for CSF leak. Three blinded radiologists reviewed examinations in random order, assessing image noise, discernibility of spinal nerve root sleeves, and overall image quality (each assessed using a scale of 0-100, with 100 denoting highest quality) and recording locations of the CVFs. Definite CVFs were defined as CVFs described in CT myelography reports using unequivocal language and having an attenuation value greater than 70 HU. For all readers, PCD CT myelography, in comparison with EID CT myelography, showed higher mean image noise (reader 1: 69.9 ± 18.5 [SD] vs 37.6 ± 15.2; reader 2: 59.5 ± 8.7 vs 49.3 ± 12.7; and reader 3: 57.6 ± 13.2 vs 42.1 ± 16.6), higher mean nerve root sleeve discernibility (reader 1: 81.6 ± 21.7 [SD] vs 30.4 ± 13.6; reader 2: 83.6 ± 10 vs 70.1 ± 18.9; and reader 3: 59.6 ± 13.5 vs 50.5 ± 14.4), and higher mean overall image quality (reader 1: 83.2 ± 20.0 [SD] vs 38.1 ± 13.5; reader 2: 80.1 ± 10.1 vs 72.4 ± 19.8; and reader 3: 57.8 ± 11.2 vs 51.9 ± 13.6) (all < .05). Eleven patients had a definite CVF. Sensitivity and specificity of EID CT myelography and PCD CT myelography for the detection of definite CVF were 45% and 96% versus 64% and 85%, respectively, for reader 1; 36% and 100% versus 55% and 96%, respectively, for reader 2; and 57% and 100% versus 55% and 93%, respectively, for reader 3. The sensitivity was significantly higher for PCD CT myelography than for EID CT myelography for reader 1 and reader 2 (both < .05) and was not significantly different between the two techniques for reader 3 ( = .45); for all three readers, specificity was not significantly different between the two modalities (all > .05). In comparison with EID CT myelography, PCD CT myelography yielded significantly improved image quality with significantly higher sensitivity for CVFs (for two of three readers), without significant loss of specificity. The findings support a potential role for PCD CT myelography in facilitating earlier diagnosis and targeted treatment of SIH, avoiding high morbidity during potentially prolonged diagnostic workups.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12124286PMC
http://dx.doi.org/10.2214/AJR.23.30673DOI Listing

Publication Analysis

Top Keywords

pcd myelography
28
eid myelography
24
image quality
16
myelography
15
reader
15
energy-integrating detector
8
photon-counting detector
8
csf-venous fistulas
8
spontaneous intracranial
8
intracranial hypotension
8

Similar Publications