Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Aims: The application of endoscopic suturing has revolutionized defect closures. Conventional over-the-scope suturing necessitates removal of the scope, placement of the device, and reinsertion. A single channel, single sequence, through-the-scope suturing device has been developed to improve this process. This study aims to describe the efficacy, feasibility, and safety of a through-the-scope suturing device for gastrointestinal defect closure.

Methods: This was a retrospective multicenter study involving 9 centers of consecutive adult patients who underwent suturing using the X-Tack Endoscopic HeliX Tacking System (Apollo Endosurgery). The primary outcomes were technical success and long-term clinical success. Secondary outcomes included adverse events, recurrence, and reintervention rates.

Results: In all, 56 patients (mean age 53.8, 33 women) were included. Suturing indications included fistula repair (n=22), leak repair (n=7), polypectomy defect closure (n=12), peroral endoscopic myotomy (POEM) site closure (n=7), perforation repair (n=6), and ulcers (n=2). Patients were followed at a mean duration of 74 days. Overall technical and long-term clinical success rates were 92.9% and 75%, respectively. Both technical and clinical success rates were 100% for polypectomies, POEM-site closures, and ulcers. Success rates were lower for the repair of fistulas (95.5% technical, 54.5% clinical), leaks (57.1%, 28.6%), and perforations (100%, 66.7%). No immediate adverse events were noted.

Conclusion: This novel, through-the-scope endoscopic suturing system, is a safe and feasible method to repair defects that are ≤3 cm. The efficacy of this device may be better suited for superficial defects as opposed to full-thickness defects. Larger defects will need more sutures and probably a double closure technique to provide a reinforcement layer.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MCG.0000000000001977DOI Listing

Publication Analysis

Top Keywords

clinical success
12
success rates
12
efficacy feasibility
8
feasibility safety
8
x-tack endoscopic
8
endoscopic helix
8
helix tacking
8
tacking system
8
endoscopic suturing
8
through-the-scope suturing
8

Similar Publications

Mobility impairment and fall concern predict wayfinding ability in persons with multiple sclerosis.

Mult Scler Relat Disord

September 2025

Department of Psychology, Wayne State University, Detroit, MI, 48202, USA; Institute of Gerontology, Wayne State University, Detroit, MI, 48202, USA; Translational Neuroscience Program, Wayne State University, Detroit, MI, 48201, USA. Electronic address:

The ability to navigate through one's environment is crucial for maintaining independence in daily life and depends on complex cognitive and motor functions that are vulnerable to decline in persons with Multiple Sclerosis (MS). While previous research suggests a role for mobility in the physical act of navigation, it remains unclear to what extent mobility impairment and perceptions of mobility constraints may modify wayfinding and the recall of environment details in support of successful navigation. Therefore, this study examined the relations among clinical mobility function, concern about falling, and recall of environment details in a clinical sample of MS.

View Article and Find Full Text PDF

Background: Mental and behavioral disorders affect approximately 28% of the adult population in Germany per year, with treatment being provided through a diverse health care system. Yet there are access and capacity problems in outpatient mental health care. One innovation that could help reduce these barriers and improve the current state of care is the use of mobile health (mHealth) apps, known in Germany as Digitale Gesundheitsanwendungen (DiGA).

View Article and Find Full Text PDF

Background: Acute respiratory infections (ARIs) are frequent reasons for medical consultations in general practice and can lead to unnecessary recontacts. Introducing new point-of-care (POC) polymerase chain reaction (PCR) diagnostic equipment may offer an attractive and efficient way of providing a more precise and exact microbial diagnosis. Successful uptake of POC PCR equipment could potentially lead to a reduction in recontacts with benefits for both staff and patients.

View Article and Find Full Text PDF

While human autopsy samples have provided insights into pulmonary immune mechanisms associated with severe viral respiratory diseases, the mechanisms that contribute to a clinically favorable resolution of viral respiratory infections remain unclear due to the lack of proper experimental systems. Using mice co-engrafted with a genetically matched human immune system and fetal lung xenograft (fLX), we mapped the immunological events defining successful resolution of SARS-CoV-2 infection in human lung tissues. Viral infection is rapidly cleared from fLX following a peak of viral replication, histopathological manifestations of lung disease and loss of AT2 program, as reported in human COVID-19 patients.

View Article and Find Full Text PDF

The integration of robotic platforms in breast oncology has witnessed substantial expansion, fueled by their inherent advantages in minimally invasive access and enhanced intraoperative maneuverability. Most of the robotic-assisted breast surgery has been performed using multi-arm robots. However, the implementation of single-port robotic (SPr) systems in mammary interventions continues to undergo rigorous clinical evaluation, particularly regarding long-term oncological safety and cost-effectiveness metrics.

View Article and Find Full Text PDF