A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Mini-Implant Insertion Using a Guide Manufactured with Computer-Aided Design and Computer-Aided Manufacturing in an Adolescent Patient Suffering from Tooth Eruption Disturbance. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Due to dental diseases, anatomical restrictions, and mixed dentition, the reduction in the number of teeth and the displacement of tooth germs pose challenges in orthodontic treatment, limiting anchorage options. The presented case demonstrates an advanced treatment solution using digital CAD/CAM-technologies and medical imaging for the creation of a mini-implant template. A 12-year-old male patient experiencing delayed tooth eruption, multiple impacted germs, and maxillary constriction underwent intraoral scanning and CBCT. Utilizing coDiagnostiX Version 10.2 software, the acquired data were merged to determine the mini-implant placement and to design the template. The template was then manufactured through stereolithography using surgical-guide material. Mini-implants were inserted using the produced appliance, enabling safe insertion by avoiding vital structures. Surgically exposed displaced teeth were aligned using a Hyrax screw appliance anchored on the mini-implants for rapid palatal expansion (RPE) and subsequently used as fixed orthodontics to align impacted teeth. The screw was activated daily for 10 weeks, resulting in a 7 mm posterior and 5 mm anterior maxillary transversal increase. Skeletal anchorage facilitated simultaneous RPE and tooth alignment, ensuring accuracy, patient safety, and appliance stability. The presented case shows a scenario in which computer-aided navigation for mini-implant positioning can enhance precision and versatility in challenging anatomical cases.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10813086PMC
http://dx.doi.org/10.3390/bioengineering11010091DOI Listing

Publication Analysis

Top Keywords

tooth eruption
8
presented case
8
mini-implant
4
mini-implant insertion
4
insertion guide
4
guide manufactured
4
manufactured computer-aided
4
computer-aided design
4
design computer-aided
4
computer-aided manufacturing
4

Similar Publications