A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

18F-FDG PET/CT anatomic and metabolic guidance in CT-guided lung biopsies. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To evaluate the role of Fluorine-18 fluorodeoxyglucose (18F-FDG) PET/CT as a metabolic guide in increasing the accuracy, diagnostic yield and safety of CT-guided percutaneous needle lung biopsy (PNB).

Methods And Materials: Retrospective analysis of 340 consecutive patients with suspicious lung nodules, masses or extensive disease that underwent lung biopsy over a 3-year period. Patients were divided into three groups; those that had PET/CT prior to the biopsy, those that had PET-CT following the biopsy and those who did not undergo PET-CT. Correlation was made with the histopathological result.

Results: 353 PNBs were performed (median lesion size 30 mm, 7-120 mm) with overall diagnostic rate of 83.9 % (95.8 % malignant). Biopsy success rate was 88.8 % with PET-CT pre-PNB, versus 78.9 % of 175 PNB without PET-CT upfront (p < 0.01 Fisher exact test). Correct targeting to PET-CT-maximum activity area (MAA) was present in 87.1 %. Biopsy success rate was 88.8 % for PNBs targeting the PET-CT-MAA region and only 52.8 % for PNBs not targeting the PET-CT-MAA (p < 0.0001). PET-CT pre-PNB had higher rates of PET-CT-MAA targeting compared to PET-CT post PNB (91.0 % v 80.0 %, p = 0.01). The availability of PET-CT before the PNB lead to significantly increased biopsy success rates in patients with a mass (OR:7.01p = 0.004), compared to a nodule (p = 0.498) or multiple nodules (p = 0.163). Patients with a PET-CT pre-PNB underwent fewer PNB passes (mean 2.6 v 3.1, p < 0.0001 Mann Whitney U). Serious complications were less common in PET-CT pre-PNB group (4.5 % v 10.9 %, p < 0.05). Pre-PNB PET-CT performance improvement applied to all 3 radiologists and was greatest for masses and infiltrative abnormalities.

Conclusion: Metabolic information provided by 18F-FDG PET/CT and PNB localisation to the PET-CT maximum activity region is associated with higher diagnostic biopsy rates especially in masses and appears to account for improved performance, less needle passes and complications when available pre-biopsy.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ejrad.2024.111315DOI Listing

Publication Analysis

Top Keywords

18f-fdg pet/ct
8
lung biopsy
8
biopsy
5
pet/ct anatomic
4
anatomic metabolic
4
metabolic guidance
4
guidance ct-guided
4
lung
4
ct-guided lung
4
lung biopsies
4

Similar Publications