Background: The measurement of aortic dimensions and their evolution are key in the management of patients with aortic diseases. Manual assessment, the current guideline-recommended method and clinical standard, is subjective, poorly reproducible, and time-consuming, limiting the capacity to track aortic growth in everyday practice. Aortic geometry mapping (AGM) via image registration of serial computed tomography angiograms outperforms manual assessment, providing accurate and reproducible 3D maps of aortic diameter and growth rate. This observational study aimed to evaluate the accuracy and reproducibility of AGM on non-gated contrast-enhanced (CE-) and cardiac- and respiratory-gated (GN-) magnetic resonance angiographies (MRA).
Methods: Patients with thoracic aortic disease followed with serial CE-MRA (n = 30) or GN-MRA (n = 15) acquired at least 1 year apart were retrospectively and consecutively identified. Two independent observers measured aortic diameters and growth rates (GR) manually at several thoracic aorta reference levels and with AGM. Agreement between manual and AGM measurements and their inter-observer reproducibility were compared. Reproducibility for aortic diameter and GR maps assessed with AGM was obtained.
Results: Mean follow-up was 3.8 ± 2.3 years for CE- and 2.7 ± 1.6 years for GN-MRA. AGM was feasible in the 93% of CE-MRA pairs and in the 100% of GN-MRA pairs. Manual and AGM diameters showed excellent agreement and inter-observer reproducibility (ICC>0.9) at all anatomical levels. Agreement between manual and AGM GR was more limited, both in the aortic root by GN-MRA (ICC=0.47) and in the thoracic aorta, where higher accuracy was obtained with GN- than with CE-MRA (ICC=0.55 vs 0.43). The inter-observer reproducibility of GR by AGM was superior compared to manual assessment, both with CE- (thoracic: ICC= 0.91 vs 0.51) and GN-MRA (root: ICC=0.84 vs 0.52; thoracic: ICC=0.93 vs 0.60). AGM-based 3D aortic size and growth maps were highly reproducible (median ICC >0.9 for diameters and >0.80 for GR).
Conclusion: Mapping aortic diameter and growth on MRA via 3D image registration is feasible, accurate and outperforms the current manual clinical standard. This technique could broaden the possibilities of clinical and research evaluation of patients with aortic thoracic diseases.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11211222 | PMC |
http://dx.doi.org/10.1016/j.jocmr.2024.100992 | DOI Listing |
JAMA Cardiol
September 2025
Department of Cardiology, Inselspital University Hospital of Bern, University of Bern, Bern, Switzerland.
Importance: Right anomalous aortic origin of a coronary artery (R-AAOCA) is a rare congenital condition increasingly diagnosed with the growing use of cardiac imaging. Due to dynamic compression of the anomalous vessel, invasive fractional flow reserve (FFR) during a dobutamine-atropine volume challenge (FFR-dobutamine) is considered the reference standard. A reliable alternative method is needed to reduce extensive invasive testing, but it remains uncertain whether noninvasive imaging can accurately assess the hemodynamic relevance of R-AAOCA.
View Article and Find Full Text PDFSurg Endosc
September 2025
Department of Surgery, Amsterdam UMC Location University of Amsterdam, Meibergdreef 9, Amsterdam, The Netherlands.
Background: Endoscopic vacuum therapy (EVT) has been established as a safe and effective treatment for anastomotic leakage. While rare, major aortic hemorrhage has been reported as a severe complication potentially associated with EVT. However, significant hemorrhages have also been observed in patients with transmural defects in the upper gastrointestinal tract, without the use of EVT.
View Article and Find Full Text PDFInflamm Res
September 2025
Department of Cardiology, Huashan Hospital, Fudan University, Shanghai, 200040, China.
Cardiovascular diseases (CVDs) are a group of conditions that significantly affect human health and are among the leading causes of death and disability worldwide. Clinical trials and basic research have demonstrated that inflammation plays a pivotal role in the development of CVDs. The inflammasome is a critical component of the innate immune system, involved in various inflammatory responses to pathogens and tissue damage.
View Article and Find Full Text PDFJACC Case Rep
September 2025
Ann & Robert H. Lurie Children's Hospital, Chicago, Illinois, USA; Northwestern Feinberg School of Medicine, Chicago, Illinois, USA.
Background: Loeys-Dietz syndrome (LDS) is a rare connective tissue disorder (CTD) with musculoskeletal, craniofacial, and cardiovascular features with a prevalence of approximately 1:50,000. Morbidity and mortality often occur earlier in patients with LDS compared to patients with other CTDs.
Case Summary: We present a teenager with subacute heart failure, 4/6 holosystolic murmur with diastolic rumble, facial differences, and arachnodactyly.
Int J Surg
September 2025
Department of Cardiovascular Surgery, The Affiliated Hospital, Southwest Medical University, Metabolic Vascular Diseases Key Laboratory of Sichuan Province, Key Laboratory of Cardiovascular Remodeling and Dysfunction, Luzhou, Sichuan, PR China.
Objective: This meta-analysis aimed to compare the perioperative safety and efficacy of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) in bicuspid aortic valve (BAV) stenosis.
Methods: We systematically analyzed studies from PubMed, Cochrane Library, Embase, and CNKI comparing TAVR and SAVR in BAV stenosis. Outcomes included postoperative mortality, complications, all-cause survival, and freedom from stroke.