Determination of output factor for CyberKnife using scintillation dosimetry and deep learning.

Phys Med Biol

UCL Medical Physics & Biomedical Engineering, London, WC1E 6BT, United Kingdom.

Published: January 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

. Small-field dosimetry is an ongoing challenge in radiotherapy quality assurance (QA) especially for radiosurgery systems such as CyberKnife. The objective of this work is to demonstrate the use of a plastic scintillator imaged with a commercial camera to measure the output factor of a CyberKnife system. The output factor describes the dose on the central axis as a function of collimator size, and is a fundamental part of CyberKnife QA and integral to the data used in the treatment planning system.. A self-contained device consisting of a solid plastic scintillator and a camera was build in a portable Pelicase. Photographs were analysed using classical methods and with convolutional neural networks (CNN) to predict beam parameters which were then compared to measurements.. Initial results using classical image processing to determine standard QA parameters such as percentage depth dose (PDD) were unsuccessful, with 34% of points failing to meet the Gamma criterion (which measures the distance between corresponding points and the relative difference in dose) of 2 mm/2%. However, when images were processed using a CNN trained on simulated data and a green scintillator sheet, 92% of PDD curves agreed with measurements with a microdiamond detector to within 2 mm/2% and 78% to 1%/1 mm. The mean difference between the output factors measured using this system and a microdiamond detector was 1.1%. Confidence in the results was enhanced by using the algorithm to predict the known collimator sizes from the photographs which it was able to do with an accuracy of less than 1 mm.. With refinement, a full output factor curve could be measured in less than an hour, offering a new approach for rapid, convenient small-field dosimetry.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6560/ad1b69DOI Listing

Publication Analysis

Top Keywords

output factor
16
factor cyberknife
8
small-field dosimetry
8
plastic scintillator
8
microdiamond detector
8
determination output
4
factor
4
cyberknife
4
cyberknife scintillation
4
scintillation dosimetry
4

Similar Publications

Automated Facial Aesthetics Evaluation: Performance of the Beauty Scanner-Face Analyzer in Measuring Symmetry and Proportions.

Aesthetic Plast Surg

September 2025

Department of Plastic and Cosmetic Surgery, Tongji Hospital, School of Medicine, Tongji University, No.389 Xincun Road, Shanghai, 200092, China.

Background: The integration of digital tools in aesthetic medicine has enhanced the precision of facial feature analysis. Using concepts like the Golden Ratio, these technologies enable more objective assessments of facial proportions and symmetry. The beauty scanner-face analyzer (BS-FA) app offers a digital approach to evaluate geometric proportions and facial alignment, providing valuable data for preoperative planning in plastic surgery and aesthetic treatments.

View Article and Find Full Text PDF

The traditional structural transformation narrative emphasizes intersectoral labour reallocation out of agriculture, ignoring whether workers exit agrifood value chains or merely migrate within them. Here we decompose multiregional input-output table data into industry- and country-specific annual labour value-added estimates by final consumer market segment, matching them with industry-specific employment data to estimate average worker compensation. Using data covering most of the global economy over 1993-2021, we report ten stylized facts about labour reallocation amid structural transformation.

View Article and Find Full Text PDF

Objective: Determine whether acute kidney injury (AKI) is associated with subsequent late-onset infection (LOI) among extremely low gestational age newborns (ELGAN).

Study Design: Secondary analysis of participants in the Preterm Erythropoietin for Neuroprotection Trial. Infants surviving ≥7 days with sufficient serum creatinine data were included.

View Article and Find Full Text PDF

Introduction: Relational continuity of care (RCC) refers to the sustained therapeutic relationship between a patient and a clinician, which fosters trust, enhances communication and facilitates the accumulation of knowledge about the patient. RCC is associated with enhanced patient outcomes, reduced hospital admissions, lower mortality rates, decreased healthcare costs and improved patient experience. Despite these benefits, reorganisations within the NHS and workforce challenges have led to an increased reliance on multidisciplinary and part-time working, resulting in fragmented care and a decline in RCC.

View Article and Find Full Text PDF

Glucagon dysregulation is a hallmark of type 2 diabetes mellitus (T2DM), yet its early hepatic effects remain unclear. Here, we demonstrate that glucagon-induced gluconeogenesis is markedly enhanced in primary hepatocytes from prediabetic Otsuka Long-Evans Tokushima Fatty (OLETF) rats, a well-established model of human T2DM. Compared to control LETO rats, OLETF hepatocytes showed significantly higher glucagon-stimulated expression of gluconeogenic genes (Pepck, G6pase, Fbp1) at both mRNA and protein levels, along with elevated glucose production.

View Article and Find Full Text PDF