A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Assessment of the tolerance angle for pedicle screw insertion. | LitMetric

Assessment of the tolerance angle for pedicle screw insertion.

Med Biol Eng Comput

Laboratoire de Biomécanique Appliquée, UMRT24 IFSTTAR, Faculté de Medecine Secteur-Nord, Aix-Marseille University, University of Gustave Eiffel, LBA, Marseille, France.

Published: April 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Cannulation process intervenes before implantation of pedicle screw and depends on the surgeon's experience. A reliable experimental protocol has been developed for the characterization of the slipping behavior of the surgical tool on the cortical shell simulated by synthetic materials. Three types of synthetic foam samples with three different densities were tested using an MTS Acumen 3 A/T electrodynamic device with a tri-axis 3 kN Kistler load cell mounted on a surgical tool, moving at a constant rotational speed of 10° mm and performing a three-step cannulation test. Cannulation angle varied between 10° and 30°. Synthetic samples were scanned after each tests, and cannulation coefficient associated to each perforation section was computed. Reproducibility tests resulted in an ICC for Sawbone samples of 0.979 (p < 0.001) and of 0.909 (p < 0.001) for Creaplast and Sawbone samples. Cannulation coefficient and maximum force in Z-axis are found the best descriptors of the perforation. Angular threshold for perforation prediction was found to be 17.5° with an area under the curve of the Receiver Operating Characteristic of 89.5%. This protocol characterizes the cannulation process before pedicle screw insertion and identifies the perforation tool angle until which the surgical tool slips on the cortical shell depending on bone quality.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s11517-023-03002-xDOI Listing

Publication Analysis

Top Keywords

pedicle screw
8
surgical tool
8
assessment tolerance
4
tolerance angle
4
angle pedicle
4
screw insertion
4
cannulation
4
insertion cannulation
4
cannulation process
4
process intervenes
4

Similar Publications