98%
921
2 minutes
20
Background: The new balloon-expandable (BE) Myval transcatheter heart valves (THV) has shown promising early results with low paravalvular leak (PVL) and permanent pacemaker implantation (PPI) rates. Limited data are available regarding its long-term performance. We aimed to compare the 2-year clinical and echocardiographic outcomes of transcatheter aortic valve replacement (TAVR) using the self-expanding (SE) Evolut R and the BE Myval THVs.
Methods: The EVAL study included 166 patients with severe aortic valve stenosis who underwent TAVR either with SE Evolut R (n = 108) or BE Myval (n = 58) THV. Primary objectives include comparison on clinical efficacy (freedom from all-cause mortality, stroke, and cardiovascular hospitalization), echocardiographic performance and PPI rates between the two THVs.
Results: At 2-year the BE Myval group showed higher clinical efficacy (86% vs. 66%,HR:2.62, 95%CI 2.2-5.1;p = 0.006), with fewer cardiac hospitalizations (3.4% vs. 13.9%,p = 0.03). No significant differences in all-cause mortality, cardiovascular mortality, or stroke rates were observed. The proportion of patients with ≥moderate PVL was significantly lower in the BE Myval compared to the SE Evolut R group (4%vs. 22%,p = 0.008). The mean transvalvular gradient was significantly higher in the SE group compared to the BE group (9.5 ± 4.3 vs. 6.9 ± 2.2 mmHg,p < 0.001), however there was no difference in the percentage of patients with a mean gradient ≥20 mmHg between the two groups.
Conclusions: Both THVs offer similar 2-year clinical outcomes. The BE Myval THV demonstrated advantages with higher clinical efficacy and lower PVL incidence. Longer follow-up and randomized trials are needed to validate these results and assess Myval's sustained performance and durability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.ijcard.2023.131701 | DOI Listing |
Multimed Man Cardiothorac Surg
September 2025
Department of Cardiothoracic Surgery, Royal Children’s Hospital, Melbourne, Australia
The patient had rheumatic heart disease, which resulted in severe aortic and mitral valve regurgitation. Repair of both valves was performed at 9 years of age. During surgery, the retracted aortic valve cusps required extension with bovine pericardial patches and suture reduction annuloplasty, and the mitral valve was repaired using a Cosgrove-Edwards (Edwards Lifesciences LLC, Irvine, CA) annuloplasty band.
View Article and Find Full Text PDFJ Thorac Cardiovasc Surg
September 2025
Division of Cardiac Surgery, Department of Surgery, Western University, London Health Science Centre, London, Ontario, Canada.
J Neuroendovasc Ther
August 2025
Department of Neurosurgery, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Hiroshima, Japan.
Objective: Endovascular treatment of cerebrovascular diseases can be challenging in patients with difficult access routes. We describe a turn-over technique using a balloon guiding catheter (BGC) via the transfemoral approach to perform neuroendovascular treatment.
Case Presentation: An 80-year-old female with a recurrent right middle cerebral artery (MCA) aneurysm after coil embolization underwent successful stent-assisted coiling via the transfemoral approach.
J Geriatr Cardiol
August 2025
Department of Bachelor of Medicine, Bachelor of Surgery, Sindh Medical College, Jinnah Sindh Medical University, Karachi, Pakistan.
Cureus
August 2025
Acute Internal Medicine, University Hospitals of North Midland, Royal Stoke University Hospital, Stoke-on-Trent, GBR.
Infective endocarditis is a potentially fatal condition that can present with non-specific symptoms and rare hematologic manifestations, posing significant diagnostic challenges. We report a compelling case of a 67-year-old male with a history of type 2 diabetes, hypertension, and hyperlipidemia who sought medical attention for a five-month history of progressive iron deficiency anemia, accompanied by weight loss, fatigue, and vague constitutional symptoms. Initial extensive workup, including computed tomography of the thorax, abdomen, and pelvis, gastroscopy, colonoscopy, and transthoracic echocardiography, failed to identify an underlying cause.
View Article and Find Full Text PDF