98%
921
2 minutes
20
Purpose: To show that variations through slice and slice profile effects are two major confounders affecting 2D dual angle maps using gradient-echo signals and thus need to be corrected to obtain accurate maps.
Methods: The 2D gradient-echo transverse complex signal was Bloch-simulated and integrated across the slice dimension including nonlinear variations in inhomogeneities through slice. A nonlinear least squares fit was used to find the factor corresponding to the best match between the two gradient-echo signals experimental ratio and the Bloch-simulated ratio. The correction was validated in phantom and in vivo at 3T.
Results: For our RF excitation pulse, the error in the factor scales by approximately 3.8% for every 10 Hz/cm variation in along the slice direction. Higher accuracy phantom maps were obtained after applying the proposed correction; the root mean square error relative to the gold standard decreased from 6.4% to 2.6%. In vivo whole-liver maps using the corrected map registered a significant decrease in gradient through slice.
Conclusion: inhomogeneities varying through slice were seen to have an impact on the accuracy of 2D double angle maps using gradient-echo sequences. Consideration of this confounder is crucial for research relying on accurate knowledge of the true excitation flip angles, as is the case of mapping using a spoiled gradient recalled echo sequence.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10952755 | PMC |
http://dx.doi.org/10.1002/mrm.29966 | DOI Listing |
Head Face Med
September 2025
Department of Oral and Maxillofacial Surgery, University Hospital Tübingen, Tübingen, Germany.
Background: The treatment of mandibular angle fractures remains controversial, particularly regarding the method of fixation. The primary aim of this study was to compare surgical outcomes following treatment with 1-plate versus 2-plate fixation across two oral and maxillofacial surgery clinics. The secondary aim was to evaluate associations between patient-, trauma-, and procedure-specific factors with postoperative complications and to identify high-risk patients for secondary osteosynthesis.
View Article and Find Full Text PDFMagn Reson Lett
May 2025
State Key Laboratory of Space Power-Sources, School of Chemistry and Chemical Engineering, Harbin Institute of Technology, Harbin, 150001, China.
Supercapacitors, comprising electrical double-layer capacitors (EDLCs) and pseudocapacitors, are widely acknowledged as high-power energy storage devices. However, their local structures and fundamental mechanisms remain poorly understood, and suitable experimental techniques for investigation are also lacking. Recently, nuclear magnetic resonance (NMR) has emerged as a powerful tool for addressing these fundamental issues with high local sensitivity and non-invasiveness.
View Article and Find Full Text PDFActa Crystallogr E Crystallogr Commun
September 2025
Institut für Anorganische und Analytische Chemie, Technische Universität Braunschweig, Hagenring 30, D-38106 Braunschweig, Germany.
In the structure of the title compound, CHN·CHNOS·CHNOS, the central pyridinic rings are approximately coplanar to the benzo-thia-zole moieties. The phenyl groups are appreciably angled to the central rings [inter-planar angles of 57.30 (3)° for the anion and 79.
View Article and Find Full Text PDFFront Bioeng Biotechnol
August 2025
The Third People's Hospital Affiliated to Fujian University of Traditional Chinese Medicine, Fuzhou City, Fujian, China.
Objective: This study investigates the biomechanical effects of long-term Tai Chi practice on the knee meniscus through biomechanical experimentation and finite element simulation, focusing on practitioners performing Knee Brushing and Twisting Step. The findings aim to establish scientific guidelines for optimizing exercise protocols in middle-aged and elderly populations.
Methods: Twenty male middle-aged and elderly practitioners were recruited, divided into a Beginner Group (BG: n = 10), and an Experienced Group (EG: n = 10).
Res Vet Sci
September 2025
Department of Veterinary Medicine, Federal University of Jatai (UFJ), Jataí, State of Goiás, Brazil.
The aim of this study was to compare the compressive forces generated by Dynamic Compression Angle-Stable Interlocking Nail (DCASIN) with those of traditional Dynamic Compression Plates (DCP) and Locking Compression Plates (LCP) using synthetic diaphyseal bone models (SDBM). Three groups were established based on the fixation method (G-DCASIN, G-DCP, and G-LCP), with implants fixed to SDBM simulating a transverse fracture, comprising 10 repetitions per group. A strain-gauge load cell was positioned in the SDBM gap to measure compressive forces in kilograms, recorded 30 s after the completion of each group-specific compression technique.
View Article and Find Full Text PDF