Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Opnurasib (JDQ-443) is a highly potent and promising KRAS inhibitor that is currently under clinical investigation. Results of the ongoing clinical research demonstrated the acceptable safety profile and clinical activity of this drug candidate as a single agent for patients with NSCLC harboring KRAS mutations. In this early stage of development, a deeper insight into pharmacokinetic properties in both preclinical and clinical investigations of this drug is very important. Thus, a reliable quantification method is required. To date, no quantitative bioanalytical assay of opnurasib was publicly available. In this study we present a validated assay to quantify opnurasib in mouse plasma and eight mouse tissue-related matrices utilizing liquid chromatography-tandem mass spectrometry. Erlotinib was used as internal standard and acetonitrile was utilized to treat 10 µl of the sample with protein precipitation in a 96-well plate format. Separation and detection were achieved using a BEH C18 column under basic chromatographic conditions and a triple quadrupole mass spectrometer, respectively. We have fully validated this assay for mouse plasma and partially for eight mouse tissue-related matrices over the range of 2-2000 ng/ml. The accuracy and precision of the assay fulfilled international guidelines (EMA & U.S. FDA) over the validated range. The method was proven selective and sensitive to quantify opnurasib down to 2 ng/ml in all investigated matrices. The recoveries of both analyte and internal standard in mouse plasma were ∼100 % with no significant matrix effect in any of the matrices. Opnurasib in mouse plasma was stable up to 12 h at room temperature, and up to 8 h at room temperature in tissue homogenates (except for kidney up to 4 h). This presented method has been successfully applied to quantify opnurasib in preclinical samples from a mouse study and demonstrated its usability to support preclinical pharmacokinetic studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1016/j.jchromb.2023.123964 | DOI Listing |