A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

First experience with the Hugo™ robot-assisted surgery system for endometriosis: A descriptive study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: The Medtronic Hugo™ Robot-assisted Surgery (RAS) system was recently approved for clinical use. We explored the safety and feasibility of this system for endometriosis surgery. The primary outcome was safe case completion without major surgical complications (Clavien-Dindo grade ≤2) and no conversion to open surgery or laparoscopy.

Material And Methods: Surgeries for endometriosis performed at the Department of Gynecology, Rigshospitalet, on the Medtronic Hugo™ RAS system were included. Two experienced robotic surgeons performed all surgeries with their usual robotic team. The variables included were patient demographics, peri- and postoperative data, complications and 30-day readmission rate. We used the IDEAL framework 1/2a for surgical innovation in this descriptive study.

Results: The first 12 patients were included. All cases were completed without intraoperative complications or conversion. Four patients experienced Clavien-Dindo grade 1 postoperative complications. No patients were re-admitted within 30 days. Median docking time (17 minutes), console time (87.5 minutes), blood loss (40 mL) and length of hospital stay (1 day) were acceptable compared with previous literature.

Conclusions: In this pilot study, we found the Medtronic Hugo™ RAS system safe and feasible for robot-assisted surgery for endometriosis. The advent of new robotic systems is welcomed to accelerate the development of technology that will advance surgical care for patients across the globe.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10823395PMC
http://dx.doi.org/10.1111/aogs.14727DOI Listing

Publication Analysis

Top Keywords

robot-assisted surgery
12
medtronic hugo™
12
ras system
12
hugo™ robot-assisted
8
system endometriosis
8
clavien-dindo grade
8
hugo™ ras
8
surgery
5
system
5
experience hugo™
4

Similar Publications