Article Abstract

Rapid, sensitive, and quantitative detection of biomarkers is needed for early diagnosis of disease and surveillance of infectious outbreaks. Here, we exploit a plasmonic syringe filter and surface-enhanced Raman spectroscopy (SERS) in the development of a rapid detection system, using human IgG as a model diagnostic biomarker. The novel assay design facilitates multiple passages of the sample and labeling solution through the detection zone enabling us to investigate and maximize sampling efficiency to the capture substrate. The vertical flow immunoassay process in this study involves the utilization of filter paper embedded with gold nanoparticles (AuNPs) to form a plasmonic substrate. Capture antibody (anti-human IgG) is then immobilized onto the prepared plasmonic paper and inserted into a vertical flow device (syringe filter holder). Sample solution is passed through the filter paper and the target antigen (human IgG) is selectively captured by the immobilized antibody to form an antibody-antigen complex. Next, functionalized AuNPs as extrinsic Raman labels (ERLs) are passed through the filter paper to label the captured biomarker molecules forming a layered structure. This sandwiched geometry enhances plasmonic coupling and SERS signal to provide highly sensitive detection of biomolecules. Systematic studies to investigate the impact of multiple infuse/withdraw cycles of the sample and labeling solutions reveal that antigen and ERL binding are maximized with 10 and 20 cycles, respectively. The optimized assay achieves a detection limit of ∼0.2 ng mL for human IgG with a total assay time of less than 5 minutes, meeting the demands for rapid point of care diagnostics. Additionally, the optimized platform was implemented in the quantitative analysis of the SARS-CoV-2 nucleocapsid protein, the typical target in commercial, FDA-approved rapid antigen tests for COVID-19.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d3an01899gDOI Listing

Publication Analysis

Top Keywords

syringe filter
12
human igg
12
filter paper
12
plasmonic syringe
8
sample labeling
8
vertical flow
8
passed filter
8
filter
6
plasmonic
5
detection
5

Similar Publications

Two patients (a 7-year-old female and a 61-year-old male) had poor intraocular pressure control after XEN gel stent implantation. During the process of filtering bleb repair, the XEN gel implant retreated into the anterior chamber, and the limbal and corneal incisions were made. After the implant in the anterior chamber was taken out, it was implanted into the anterior chamber again from the original scleral tunnel for the female patient, while it was re-punctured into the anterior chamber with a 1-ml syringe needle at another site for the male patient.

View Article and Find Full Text PDF

To analyze the effect of fasting on volume, growth factor, and lipid concentration in eye drops derived from autologous serum (AS) and leukocyte-poor platelet-rich plasma (LP-PRP). To assess changes in protein and growth factor concentration after filtration with three different syringe filters and after complement inactivation with heat. Blood samples from 10 volunteers after a fasting and nonfasting period were harvested on two separate visits.

View Article and Find Full Text PDF

Cold storage is a preferred method for short-term preservation of ram spermatozoa due to its superior fertility rates compared to cryopreservation. This study aimed to optimise the conditions for ram sperm preservation by evaluating the effects of osmolarity and egg yolk (EY) concentration in a syringe-filtered extender. In part A, semen samples were extended with solutions of varying osmolarities (330, 360, 390 and 420 mOsm/kg water).

View Article and Find Full Text PDF

This study exploited the water repelling hydrophobic nature of polycaprolactone (PCL) fibers for efficient filtration of water-based fluids toward development of an affordable sterile membrane filter by the process of electrospinning. Electrospun (ES) nanosized fibrous membranes of different thicknesses presented high force at break and minimal elongation supported syringe filtration. The membrane hydrophobicity facilitated easy filtration of small volumes of biological fluids (∼1 mL) without any wetting media loss.

View Article and Find Full Text PDF

Amine-Modified Diatomaceous Earth Syringe Platform (DeSEI) for Efficient and Cost-Effective EV Isolation.

Int J Mol Sci

July 2025

Department of Biotechnology, College of Life Science and Biotechnology, Yonsei University, Seoul 03722, Republic of Korea.

Conventional methods for isolating extracellular vesicles (EVs) are often limited by long processing times, a low purity, and a reliance on specialized equipment. To overcome these challenges, we developed the DeSEI (amine-functionalized Diatomaceous earth-based Syringe platform for EV Isolation), a novel platform employing low-cost, amine-functionalized diatomaceous earth (ADe) within a simple syringe-filter system. The capture mechanism leverages the electrostatic interaction between the positively charged ADe and the negatively charged EV surface, enabling a rapid and efficient isolation.

View Article and Find Full Text PDF