A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effects of Augmented Reality on Thoracolumbar Pedicle Screw Instrumentation Across Different Levels of Surgical Experience. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Objective: Augmented reality (AR) is an emerging technology that may accelerate skill acquisition and improve accuracy of thoracolumbar pedicle screw placements. We aimed to quantify the relative assistance of AR compared with freehand (FH) pedicle screw accuracy across different surgical experience levels.

Methods: A spine fellowship-trained and board-certified attending neurosurgeon, postgraduate year 4 neurosurgery resident, and second-year medical student placed 32 FH and 32 AR-assisted thoracolumbar pedicle screws in 3 cadavers. A cableless, voice-activated AR system was paired with a headset. Accuracy was assessed using χ analysis and the Gertzbein-Robbins scale. Angular error, distance error, and time per pedicle screw were collected and compared.

Results: The attending neurosurgeon had 91.6% (11/12) clinically acceptable (Gertzbein-Robbins scale A or B) insertion in both FH and AR groups; the resident neurosurgeon had 100% (9/9) FH and AR in both cases; the medical student had 72.3% (8/11) FH accuracy and 81.8% (9/11) AR accuracy. The medical student displayed significantly lower ideal (Gertzbein-Robbins scale A) FH accuracy compared with the resident neurosurgeon (P = 0.017) and attending neurosurgeon (P = 0.005), but no difference when using AR. FH screw placement was faster by both the attending neurosurgeon (median 46 seconds vs. 94.5 seconds, P = 0.0047) and the neurosurgery resident neurosurgeon (median 144 seconds vs. 140 seconds, P = 0.05). Total clinically acceptable AR and FH accuracy was 90.6% (29/32) and 87.5% (28/32), respectively (P = 0.69).

Conclusions: AR screw placement allowed an inexperienced medical student to double their accuracy in 1 training session. With subsequent iterations, this promising technology could serve as an important tool for surgical training.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.wneu.2023.11.100DOI Listing

Publication Analysis

Top Keywords

pedicle screw
16
attending neurosurgeon
16
medical student
16
thoracolumbar pedicle
12
gertzbein-robbins scale
12
resident neurosurgeon
12
augmented reality
8
surgical experience
8
accuracy
8
neurosurgery resident
8