A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Angled BIO-RSA leads to better inclination and clinical outcomes compared to Standard BIO-RSA and eccentric reaming: A comparative study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Two surgical techniques were compared : Standard BIO-RSA, performed with a glenoid eccentric reaming along with a cylindric bone graft augmentation vs. the Angled BIO-RSA, performed with a glenoid concentric reaming and a defect correction with an angled bone graft.

Methods: Patients undergoing RSA from January 2016 to April 2019, with one of the two techniques being performed, were retrospectively reviewed. Glenoids were classified according to Favard. Clinical (Constant-Murley, VAS and ROM) and radiographic (superior tilt correction) data were collected pre-operatively and at 12 months post-operatively.

Results: 141 shoulders were included. Angled BIO-RSA group showed statistically significant better outcomes in terms of forward flexion (149.9° Vs 139.3°) and abduction (136.4° Vs 126.7°). The use of an Angled BIO-RSA showed a statistically significant better superior tilt correction (1.252° Vs 4.09°). Angled BIO-RSA, leads to a better inclination correction and a mean postoperative tilt value inferior to 5° in E1 and E3 differently from standard BIO-RSA.

Discussion: Both techniques were able to correct glenoid superior inclination with excellent postoperative short-term results. However, angled BIO-RSA technique appears to be more effective in ensuring a correct inclination of the prosthetic glenoid component with better clinical outcomes.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10649506PMC
http://dx.doi.org/10.1177/17585732211067156DOI Listing

Publication Analysis

Top Keywords

angled bio-rsa
24
bio-rsa leads
8
leads better
8
better inclination
8
clinical outcomes
8
compared standard
8
standard bio-rsa
8
eccentric reaming
8
bio-rsa performed
8
performed glenoid
8

Similar Publications