Article Abstract

Purpose: Angular and longitudinal deformities of leg alignment create excessive stresses across joints, leading to pain and impaired function. Multiple measurements are used to assess these deformities on anteroposterior (AP) full-length radiographs. An artificial intelligence (AI) software automatically locates anatomical landmarks on AP full-length radiographs and performs 13 measurements to assess knee angular alignment and leg length. The primary aim of this study was to evaluate the agreements in LLD and knee alignment measurements between an AI software and two board-certified radiologists in patients without metal implants. The secondary aim was to assess time savings achieved by AI.

Methods: The measurements assessed in the study were hip-knee-angle (HKA), anatomical-tibiofemoral angle (aTFA), anatomical-mechanical-axis angle (AMA), joint-line-convergence angle (JLCA), mechanical-lateral-proximal-femur-angle (mLPFA), mechanical-lateral-distal-femur-angle (mLDFA), mechanical-medial-proximal-tibia-angle (mMPTA), mechanical-lateral-distal-tibia- angle (mLDTA), femur length, tibia length, full leg length, leg length discrepancy (LLD), and mechanical axis deviation (MAD). These measurements were performed by two radiologists and the AI software on 164 legs. Intraclass-correlation-coefficients (ICC) and Bland-Altman analyses were used to assess the AI's performance.

Results: The AI software set incorrect landmarks for 11/164 legs. Excluding these cases, ICCs between the software and radiologists were excellent for 12/13 variables (11/13 with outliers included), and the AI software met performance targets for 11/13 variables (9/13 with outliers included). The mean reading time for the AI algorithm and two readers, respectively, was 38.3, 435.0, and 625.0 s.

Conclusion: This study demonstrated that, with few exceptions, this AI-based software reliably generated measurements for most variables in the study and provided substantial time savings.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00256-023-04502-5DOI Listing

Publication Analysis

Top Keywords

leg length
16
knee angular
8
angular alignment
8
alignment leg
8
measurements assess
8
full-length radiographs
8
time savings
8
outliers included
8
measurements
7
software
7

Similar Publications

Optimum Push-off for Uneven Walking Based on the Just-in-Time Strategy: Walking with Interrupted Push-Off is Mechanically Costly.

J Biomech Eng

September 2025

Department of Biomedical Engineering, Schulich School of engineering, University of Calgary, AB, Canada; Cumming School of Medicine, University of Calgary, AB, Canada.

Using a powered simple walking model (point mass with rigid massless legs), the optimal analytical push-off was derived based on walking speed and step elevation changes. It was observed that higher speeds increased the available push-off to attain greater step-up e.g.

View Article and Find Full Text PDF

The main objective of this study was to investigate how different horizontal jump exercises relate to sprint performance in female athletes, and whether these relationships differ between sprinters and team sport athletes. Twelve female sprinters (age 18.9 ± 3.

View Article and Find Full Text PDF

Gait asymmetries in children and adolescents with mild leg length discrepancy.

Gait Posture

September 2025

Laboratory for Motion Analysis, Department of Paediatric Orthopaedics, Children's Hospital of Eastern Switzerland, St. Gallen, Switzerland; Department of Orthopaedics and Traumatology, Cantonal Hospital St. Gallen, Switzerland.

Background: Leg length discrepancy (LLD) is a common orthopedic condition, yet its clinical significance remains debated. While severe LLD is typically managed surgically, the impact of mild LLD (< 2 cm) on gait asymmetry in children is not well understood.

Research Question: This study aims to assess the relationship between mild LLD (< 2 cm) and gait asymmetries in children and adolescents and to compare these asymmetries to those observed in typically developing children (TDC).

View Article and Find Full Text PDF

Background: Lateral ankle sprains often progress to functional ankle instability (FAI). Obstacle-crossing could pose greater challenges for individuals with FAI due to significant impairments in ankle kinesthesia and joint position sense. While existing studies have focused on level-ground gait characteristics in FAI, the postural control strategies underlying obstacle-crossing remain unclear, and the impact of obstacle height on these strategies has not been investigated.

View Article and Find Full Text PDF

Objectives: Early endovenous intervention of the saphenous system improves healing and recurrence of venous leg ulcers (CEAP-6). As ablative methods continue to evolve, it is essential to identify outcome differences between the various techniques. This study aims to compare wound healing rates between primary non-thermal [cyanoacrylate glue (CAG) or commercial polidocanol microfoam ablation (MFA)] and thermal with adjunct MFA.

View Article and Find Full Text PDF