Background: To investigate the difference between the predicted preoperative corneal ablation depth and the measured ablation depth for femtosecond laser in situ keratomileusis (FS-LASIK) in patients with different degrees of myopia, and to analyze the source of the difference.
Methods: A total of 55 patients (109 eyes) were included in this study. Multiple logistics regression was applied to analyze the sources affecting postoperative refractive outcomes. The difference between the preoperative predicted corneal ablation depth and the 1-day postoperative ablation depth in patients with different degrees of myopia was explored using linear regression. Corneal biomechanical parameters influencing error in ablation depth calculation were examined using multiple linear regression.
Results: One hundred and nine eyes were divided into low to moderate myopia (55 eyes, myopia of 6 D or less), high myopia (45 eyes, myopia ranging from 6 D to a maximum of 9 D), and very high myopia group (9 eyes, myopia greater than 9 D) based on preoperative refractive error (spherical equivalent). Postoperative visual outcomes were comparable among the three groups of patients, with no significant difference in uncorrected visual acuity (UCVA). We did find notable disparities in spherical equivalent (SE) and central corneal thickness (CCT) in patients with different degrees of myopia at 1 day postoperatively (all p < 0.001). Logistic regression analysis showed that error in ablation depth calculation was an independent risk factor for refractive outcomes one day after surgery (OR = 1.689, 95% CI: 1.366 - 2.089). There was a substantial discrepancy in error in ablation depth calculation at 1 day postoperatively between the three groups. The measured ablation depth of the laser platform was lower than the predicted ablation depth in the low to moderate myopia and very high myopia groups, but the opposite was true in the high myopia group. Pre-operative SE (p < 0.001) and corneal front minimum radius of curvature (Front Rmin) (p = 0.007) obviously influenced the error in ablation depth calculation.
Conclusions: Error in ablation depth calculation values vary significantly between patients with different degrees of myopia and correlate highly with preoperative SE and Front Rmin. At the same time, the available evidence suggests that error in ablation depth calculation is an influential factor in postoperative refractive status, so it is imperative to control error in ablation depth calculation.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10642044 | PMC |
http://dx.doi.org/10.1186/s12886-023-03200-z | DOI Listing |
PLOS Glob Public Health
September 2025
Department of Child, Family, and Population Health Nursing, School of Nursing, University of Washington, Seattle, Washington, United States of America.
Cervical cancer continues to be a major global threat to women's health, with approximately 660,000 women diagnosed annually, 94% of whom are in low- and middle-income countries (LMICs). The high disease burden in LMICs is partly due to suboptimal adoption and widespread implementation of effective preventive interventions. This study explored drivers of implementation success and failure for a future single-visit, screen, and treat approach with thermal ablation (SV-SAT + TA), referred to as TIBA in Kenya.
View Article and Find Full Text PDFJ Refract Surg
September 2025
Department of Refractive Surgery, Shanghai Aier Eye Hospital, Shanghai.
Purpose: To analyze the effects of ablation interruption on ablation depths and clinical refractive outcomes to characterize the impact of ambient temperature changes and ablation interruption on ocular surface temperature (OST) during excimer laser ablation.
Methods: This prospective study was conducted on laser ablations in polymethylmethacrylate (PMMA) plates and porcine corneas to simulate laser in situ keratomileusis (LASIK) treatments using the EX500 laser (Alcon Laboratories, Inc) at ambient temperatures of 18, 20, and 22 °C. Ablation interruption was performed for 1, 2, 3, 4, and 5 seconds at the 10th second of the treatment of -9.
Anal Chem
September 2025
State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China.
Deciphering the multicomponent of cell membranes at the single-cell level is critical for understanding pathological mechanisms such as tumor metastasis, yet remains technically daunting due to the membrane's nanoscale thickness and ultralow molecular abundance. Here, we introduce a surface-assisted vacuum ultraviolet laser desorption-ionization mass spectrometry imaging (SAVUVDI-MSI) platform that overcomes long-standing challenges of cytoplasmic interference and insufficient sensitivity. Leveraging the nanoscale depth profiling capability of VUV-LDI, we achieve precise ablation of a single-cell membrane.
View Article and Find Full Text PDFSurg Oncol
September 2025
Department of Breast Surgery at Northwestern Medical Group, USA.
Importance: Breast-conserving therapy (BCT) results in reoperation in ∼20 % of cases due to positive margins, and a 7-13 % recurrence risk at 5 years persists despite negative margins and radiation. Enhancing margin treatment is critical to reducing local recurrence and improving survival.
Objective: To optimize and evaluate the performance of a Saline-coupled Intraoperative Radiofrequency Ablation (SIRA) device in producing uniform 1 cm ablations in lumpectomy cavities and compare it to prior-generation RFA technology in previous clinical studies.
EuroIntervention
September 2025
Dobney Hypertension Centre, Medical School - Royal Perth Hospital Unit and RPH Research Foundation, The University of Western Australia, Perth, WA, Australia and Department of Cardiology and Department of Nephrology, Royal Perth Hospital, Perth, WA, Australia.
Background: Overactivity of the hepatic and renal sympathetic nerves is associated with chronic cardiovascular and metabolic conditions, including hypertension.
Aims: We studied the effect of combined renal and hepatic denervation through treatment of the common hepatic artery and the renal arteries.
Methods: Denervation was performed in the common hepatic artery and both renal arteries and their major branch vessels in normotensive swine using the same multielectrode radiofrequency (RF) ablation catheter (Symplicity Spyral).