A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Heat sink effects in thyroid bipolar radiofrequency ablation: an ex vivo study. | LitMetric

Heat sink effects in thyroid bipolar radiofrequency ablation: an ex vivo study.

Sci Rep

Department of Nuclear Medicine, University Hospital Frankfurt, Goethe University, Theodor Stern Kai 7, 60590, Frankfurt, Germany.

Published: November 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The study aimed to investigate heat sink effects in radiofrequency ablation (RFA) under thyroid-specific conditions. In an ex vivo model, bovine thyroid lobes were ablated using bipolar RFA with 2.0 kJ energy input at a power level set to 10 W (n = 35) and 25 W (n = 35). Glass vessels (3.0 mm outer diameter) placed within the ablation zone were used to deliver tissue perfusion at various flow rates (0, 0.25, 0.5, 1, 5, 10, 20 ml/min). Temperature was measured in the proximity of the vessel (T) and in the non-perfused contralateral region of the ablation zone (T), at equal distances to the ablation electrode (d = 8 mm). Maximum temperature within the perfused zone was significantly lowered with T ranging from 54.1 ± 1.5 °C (20 ml/min) to 56.9 ± 1.5 °C (0.25 ml/min), compared to T from 63.2 ± 3.5 °C (20 ml/min) to 63.2 ± 2.6 °C (0.25 ml/min) (10 W group). The cross-sectional ablation zone area decreased with increasing flow rates from 184 ± 12 mm (0 ml/min) to 141 ± 20 mm (20 ml/min) at 10 W, and from 207 ± 22 mm (0 ml/min) to 158 ± 31 mm (20 ml/min) in the 25 W group. Significant heat sink effects were observed under thyroid-specific conditions even at flow rates ≤ 1 ml/min. In thyroid nodules with prominent vasculature, heat dissipation through perfusion may therefore result in clinically relevant limitations to ablation efficacy.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10630443PMC
http://dx.doi.org/10.1038/s41598-023-45926-2DOI Listing

Publication Analysis

Top Keywords

heat sink
12
sink effects
12
ablation zone
12
radiofrequency ablation
8
thyroid-specific conditions
8
flow rates
8
ablation
7
20 ml/min
5
heat
4
effects thyroid
4