A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

International Consensus Recommendations for Safe Use of LAMS for On- and Off-Label Indications Using a Modified Delphi Process. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: The study aimed to develop international consensus recommendations on the safe use of lumen-apposing metal stents (LAMSs) for on- and off-label indications.

Methods: Based on the available literature, statements were formulated and grouped into the following categories: general safety measures, peripancreatic fluid collections, endoscopic ultrasound (EUS)-biliary drainage, EUS-gallbladder drainage, EUS-gastroenterostomy, and gastric access temporary for endoscopy. The evidence level of each statement was determined using the Grading of Recommendations Assessment, Development, and Evaluation methodology.International LAMS experts were invited to participate in a modified Delphi process. When no 80% consensus was reached, the statement was modified based on expert feedback. Statements were rejected if no consensus was reached after the third Delphi round.

Results: Fifty-six (93.3%) of 60 formulated statements were accepted, of which 35 (58.3%) in the first round. Consensus was reached on the optimal learning path, preprocedural imaging, the need for airway protection and essential safety measures during the procedure, such as the use of Doppler, and measurement of the distance between the gastrointestinal lumen and the target structure. Specific consensus recommendations were generated for the different LAMS indications, covering, among others, careful patient selection, the preferred size of the LAMS, the need for antibiotics, the preferred anatomic location of the LAMS, the need for coaxial pigtail placement, and the appropriate management of LAMS-related adverse events.

Discussion: Through a modified international Delphi process, we developed general and indication-specific experience- and evidence-based recommendations on the safe use of LAMS.

Download full-text PDF

Source
http://dx.doi.org/10.14309/ajg.0000000000002571DOI Listing