A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Model of implementing proficiency testing in Vietnam, a developing country. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Backgrounds And Aims: The aim of this study is to provide a good approach for a quantitative EQA scheme assigned value with limited resources.

Materials And Methods: Twelve lyophilized EQA items were distributed to participants in 2021 from North to Southeast Vietnam to measure the concentration of nine parameters, including glucose, urea, creatinine, cholesterol, triglyceride, uric acid, AST, ALT, and GGT. The consensus value of the expert group and all participants were calculated and statistically compared to choose the most appropriate consensus value.

Results: Fifty-nine laboratories attended the EQA scheme, including an expert group using automatic biochemistry analyzers (AAs) and all participants with auto and semi-auto biochemistry (SAA) analyzers. Consensus values of six per nine parameters were different between the two groups for at least two EQA items, including glucose, creatinine, cholesterol, uric acid, AST, and ALT. The coefficients of variation of glucose, urea, creatinine, triglycerides, uric acid, and GGT in the expert group were significantly lower than those in all the participants.

Conclusion: Using the consensus values of expert groups as the assigned values of the EQA program is a relevant strategy to increase testing quality in developing countries with limited resources, such as Vietnam.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10598689PMC
http://dx.doi.org/10.1016/j.plabm.2023.e00339DOI Listing

Publication Analysis

Top Keywords

uric acid
12
expert group
12
eqa scheme
8
eqa items
8
including glucose
8
glucose urea
8
urea creatinine
8
creatinine cholesterol
8
acid ast
8
ast alt
8

Similar Publications