A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Predictive Factors for Subjective Vertigo Following Cochlear Implantation: A Regional Multicenter Cohort Study of 395 Patients. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Cochlear implantation (CI) is generally accepted as having a low rate of postoperative complications, but between 9.3% and 13% of cases experience vertigo postoperatively. This study aimed to examine patient, surgical, and device factors contributing toward the risk of postoperative vertigo.

Methodology: A retrospective review was conducted of adult patients who underwent cochlear implant in a regional area of New South Wales from 2007 to 2018. A total of 395 cochlear implant cases were included in the final study.

Results: The overall incidence of vertigo at 3 months of follow-up was 7.1% (n = 28/395). No difference was identified in this study between rates of postoperative vertigo between device factors, including implant make (Cochlear vs. Med-El), electrode shape (perimodiolar vs. straight), and electrode model. No significant difference was found also for surgical factors such as the number of electrode rings inserted, side of implantation, or surgical approach of tympanic ramp (round window insertion vs. cochleostomy).A higher percentage of patients with preoperative vertigo experienced vertigo postoperatively (18.4%, n = 7/38), compared with the population without preoperative vertigo (6.0%, n = 21/352) ( p = 0.005). Patients with previous mastoid surgery also reported a higher rate of postoperative vertigo (20%, n = 9/45) compared with those who had not had mastoid surgery (5.43%, n = 19/350) ( p = 0.006). The mean age of patients experiencing postoperative vertigo was higher than the population without postoperative symptoms (67 vs. 63).

Conclusion: This study of a large multicenter population outlines that patient factors are more critical than surgical or device factors when considering risk factors for vertigo post-cochlear implant.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAO.0000000000004036DOI Listing

Publication Analysis

Top Keywords

device factors
12
postoperative vertigo
12
vertigo
10
cochlear implantation
8
rate postoperative
8
vertigo postoperatively
8
surgical device
8
cochlear implant
8
preoperative vertigo
8
mastoid surgery
8

Similar Publications