A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Type 1 and Type 2 Diabetes Measurement Using Human Face Skin Region. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aim: Analyse the diabetes mellitus (DM) of a person through the facial skin region using vision diabetology. Diabetes mellitus is caused by persistent high blood glucose levels and related complications, which show variation in facial skin regions due to reduced blood flow in the facial arteries. . In this study, 200 facial images of diabetes patients with skin conditions such as Bell's palsy, rubeosis faciei, scleroderma, and vitiligo were collected from existing face videos. Moreover, face images are collected from diabetic persons in India. Viola Jones' face-detecting algorithm extracts face skin regions from a diabetic person's face image in video frames. The affected skin area on the diabetic person's face is detected using HSV colour model segmentation. The proposed multiwavelet transform convolutional neural network (MWTCNN) extracts the features for diabetic measurement from up- and downfacial scaled images of diabetic persons.

Results: The existing deep learning models are compared with the proposed MWTCNN model, which provides the highest accuracy of 98.3%.

Conclusion: The facial skin region-based diabetic measurement avoids pricking of the serum and is used for continuous glucose monitoring.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10547572PMC