Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Purpose: To compare the genomic testing based on specimens obtained from percutaneous core-needle biopsy (CNB) before and immediately after coaxial microwave ablation (MWA) in solid non-small cell lung cancer (NSCLC), and to investigate the diagnostic performance of CNB immediately after coaxial MWA in solid NSCLC.
Methods: Coaxial MWA and CNB were performed for NSCLC patients, with a power of 30 or 40 watts (W) in MWA between the pre- and post-ablation CNB, followed by continuous ablation after the second CNB on demand. The paired specimens derived from the same patient were compared for pathological diagnosis and genomic testing. DNA/RNA extracted from the paired specimens were also compared.
Results: A total of 33 NSCLC patients with solid lesions were included. There were two patients (6.1%) without atypical cells and three patients (9.1%) who had the technical failure of genomic testing in post-ablation CNB. The concordance rate of pathological diagnosis between the twice CNB was 93.9% (kappa = 0.852), while that of genomic testing was 90.9% (kappa = 0.891). For the comparisons of DNA/RNA extracted from pre- and post-ablation CNB in 30 patients, no significant difference was found when the MWA between twice CNB has a power of 30 or 40 W and ablation time within five minutes (P = 0.174).
Conclusions: If the pre-ablation CNB presented with a high risk of pneumothorax or hemorrhage, the post-ablation CNB could be performed to achieve accurate pathological diagnosis and genomic testing and the maximum effect of ablation, which might allow for the diagnosis of genomic testing in 90.9% of solid NSCLC.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10548670 | PMC |
http://dx.doi.org/10.1186/s40644-023-00610-6 | DOI Listing |