A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Biventricular Tissue Tracking with Cardiovascular Magnetic Resonance: Reference Values of Left- and Right-Ventricular Strain. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We derived reference values of left-ventricular (LV) and right-ventricular (RV) strain parameters in a cohort of 100 healthy subjects by feature tracking cardiac magnetic resonance (FT-CMR). Global and regional strain values were calculated for the LV; circumferential and radial strain parameters were derived from the short-axis (SAX) stack, while longitudinal and radial strain parameters were assessed in three long-axis (LAX) views. Only global longitudinal strain (GLS) was calculated for the RV. Peak global LV circumferential strain was -16.7% ± 2.1%, LV radial strain was 26.4% ± 5.1%, LV radial strain was 31.1% ± 5.2%, LV GLS was -17.7% ± 1.9%, and RV GLS was -23.9% ± 4.1%. Women presented higher global LV and RV strain values than men; all strain values presented a weak relationship with body surface area, while there was no association with age or heart rate. A significant association was detected between all LV global strain measures and LV ejection fraction, while RV GLS was correlated to RV end-diastolic volume. The intra- and inter-operator reproducibility was good for all global strain measures. In the regional analysis, circumferential and radial strain values resulted higher at the apical level, while longitudinal strain values were higher at the basal level. The assessment of cardiac deformation by FT-CMR is feasible and reproducible and gender-specific reference values should be used.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10527573PMC
http://dx.doi.org/10.3390/diagnostics13182912DOI Listing

Publication Analysis

Top Keywords

strain values
20
radial strain
20
strain
15
reference values
12
strain parameters
12
global strain
12
magnetic resonance
8
values
8
right-ventricular strain
8
circumferential radial
8

Similar Publications