A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Coefficient of variation of T2-weighted MRI may predict the prognosis of malignant peripheral nerve sheath tumor. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: We investigated whether non-enhancement MRI features, including measurement of the heterogeneity of the tumor with MR T2 imaging by calculating coefficient of variation (CV) values, were associated with the prognosis of non-metastatic malignant peripheral nerve sheath tumors (MPNST).

Methods: This retrospective study included 42 patients with MPNST who had undergone surgical resection (mean age, 50 years ± 21; 20 male participants). Non-enhancement MR images were evaluated for signal intensity heterogeneity on T1- and T2-weighted imaging, tumor margin definition on T1- and T2-weighted imaging, peritumoral edema on T2-weight imaging, and CV. We measured the signal intensities of MR T2-weighted images and calculated the corresponding CV values. CV is defined as the ratio of the standard deviation to the mean. The associations between factors and overall survival (OS) were investigated via the Kaplan-Meier method with log-rank tests and the Cox proportional hazards model.

Results: The mean CV value of MR T2 images was 0.2299 ± 0.1339 (standard deviation) (range, 0.0381-0.8053). Applying receiver operating characteristics analysis, the optimal cut-off level for CV value was 0.137. This cut-off CV value was used for its stratification into high and low CV values. At multivariate survival analysis, a high CV value (hazard ratio = 3.63; 95% confidence interval = 1.16-16.0; p = 0.047) was identified as an independent predictor of OS.

Conclusion: The CV value of the signal intensity of heterogenous MPNSTs MR T2-weighted images is an independent predictor of patients' OS.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00256-023-04457-7DOI Listing