Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Objectives: Working Group 5 was convened to discuss and find consensus on the topics of implant placement and loading protocols associated with single missing teeth in the anterior maxilla (aesthetic zone). Consensus statements, clinical recommendations, patient perspectives and future research suggestions were developed and presented to the plenary for discussion and approval.
Materials And Methods: Two systematic reviews were developed and submitted prior to the conference. The group considered in detail the systematic reviews and developed statements, clinical recommendations, patient perspectives and future research suggestions based on the findings of the reviews and experience of group members. Definitive versions were developed after presentation to and discussion by the plenary.
Results: Five consensus statements were developed and approved from each systematic review. Twelve clinical recommendations were developed by the group based on both reviews and experience. Three patient perspectives were developed, and five suggestions made for future research.
Conclusions: Based on the findings of the systematic reviews and experience of group members, the Type 1A protocol (immediate placement and immediate loading), when utilized in the anterior maxilla under favorable conditions, is considered predictable and is associated with high survival rates. The procedure is considered clinically viable and is associated with aesthetic outcomes, although surgical, technical, and biological complications can occur.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/clr.14137 | DOI Listing |