A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

TiO-guanine as a new amalgamation compound for fabrication of a disposable biosensor with high sensitivity and rapid detection of H1N1 swine flu virus. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A TiO-guanine nanocomposite (TG NC)-based electrochemical biosensor was immobilized with hemagglutinin (HA) gene specific probe with 5' NH group on screen-printed gold electrode (probe(ss)DNA-TG-SPGE). The modified biosensor was examined for H1N1 swine flu virus. TG NCs along with precursors were characterized spectroscopically and morphologically by employing several approaches. Electrochemical investigations were performed with the help of cyclic voltammetric (CV) and electrochemical impedance spectroscopy (EIS) in 0.1 M phosphate buffer saline (PBS; pH 7.4) with 1 µM methylene blue (MB) redox indicator. For better detection of single-stranded virus DNA, the modified electrode was optimized at various concentrations, pH, and scan rates. The modified biosensor showed high sensitivity (40.32 μA/ng.cm), low LOD (0.00024 ng/6 µL), and broad linear range 0.0002-20 ng/6µL with coefficient of determination of R=0.9981 for H1N1 virus detection. The HA gene-modified biosensor presented decent stability and specificity against different infectious pathogens including H3N2 virus and human DNA with negative response. Furthermore, the modified biosensor also responded well for real sample target DNA detection with a recovery of >96%. The simply designed HA gene-modified biosensor transduces decreased current response towards target-specific (ss)DNA binding and could be used as a rapid detection tool for H1N1 swine flu virus diagnosis.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00604-023-05984-9DOI Listing

Publication Analysis

Top Keywords

h1n1 swine
12
swine flu
12
flu virus
12
modified biosensor
12
biosensor high
8
high sensitivity
8
rapid detection
8
gene-modified biosensor
8
biosensor
7
virus
6

Similar Publications