A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Implementation and evaluation of the AAPM TG 111 for radiation dosimetry in a state-of-the-art C-arm cone beam CT system. | LitMetric

Implementation and evaluation of the AAPM TG 111 for radiation dosimetry in a state-of-the-art C-arm cone beam CT system.

J Radiol Prot

University of Crete, School of Medicine, Department of Medical Physics, Heraklion, Crete, Greece.

Published: September 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The aim of this study was to assess the dosimetric characteristics of a state-of-the-art C-arm cone beam computed tomography (CBCT) system using the methodology proposed by the American Association of Physicists in Medicine (AAPM) Task Group (TG) 111. The dose measurement methodology described in AAPM TG 111 for wide cone beam acquisitions without table translation was employed to estimate equilibrium beam length (αeq‾) and equilibrium dose (feq‾) in various interventional task-specific protocols with different tube arc projection geometries. Dose profiles were derived from point dose measurements in the centre and peripheral locations of the ICRU/AAPM and standard polymethyl methacrylate (PMMA) body phantom. Dose measurements were performed in phantom and free-in-air using a solid-state point detector. Monte Carlo (MC) based simulation dosimetry was performed to quantify the inhomogeneous dose patterns imparted in the phantoms. Estimatedαeq‾andfeq‾on the ICRU/AAPM phantom was up to 49.4 cm and 6.17 mGy/100 mAs, respectively. Corresponding values determined on the PMMA phantom were 139 cm and 8.8 mGy/100 mAs, respectively. Free-in-air dose measurement ranged from 1.43 mGy/100 mAs to 5.93 mGy/100 mAs. Per cent difference inαeq‾andfeq‾between MC simulation and solid-state point detector measurement methods in the ICRU/AAPM phantom were within 16% and 18%, respectively. Manufacturers can use the presented methodology to characterize the dosimetric properties of C-arm CBCT systems. Clinical medical physicists may follow this methodology to verify corresponding data provided by the manufacturer and check for C-arm CBCT system performance dosimetric consistency.

Download full-text PDF

Source
http://dx.doi.org/10.1088/1361-6498/acfaa9DOI Listing

Publication Analysis

Top Keywords

mgy/100 mas
16
cone beam
12
aapm 111
8
state-of-the-art c-arm
8
c-arm cone
8
cbct system
8
dose measurement
8
dose measurements
8
solid-state point
8
point detector
8