A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Effect of Tooth Brushing Cycles and Dentifrice Fluoride Concentration on a Glazed CAD/CAM Ceramic. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To evaluate the effect of tooth brushing and dentifrice fluoride (F-) concentration on changes in color and translucency (ΔE00 and ΔT00, respectively), surface gloss (GS), surface roughness (Sa), and microstructure of a glazed CAD/CAM ceramic.

Materials And Methods: Ceramic blocks (e.max/CAD) were sectioned into rectangular plates (14 x 12 x 1 mm), and one surface of each sample was glazed. Samples were divided into three groups according to the F- concentration in the dentifrice (0, 1,100, and 5,000 μg/g) and were then subjected to 60,000 tooth brushing cycles. Luminosity and color were measured using a spectrophotometer at baseline and after every 20,000 cycles to obtain their ΔE00 and ΔT00 values. Another set of samples was prepared to measure the GS with a gloss meter and the Sa with a confocal laser microscope. The GS and Sa results were subjected to analysis of variance, Tukey test, and Dunnett test (α = .05).

Results: After 60,000 tooth brushing cycles, all of the variables were clinically acceptable, and there were no significant differences in the ΔE00, ΔT00, GS, or Sa among the fluoridated dentifrices. The GS values decreased significantly as the number of tooth brushing cycles increased.

Conclusion: The ΔE00, ΔT00, GS, and Sa values were all clinically acceptable after the glazed e.max/CAD ceramic had been subjected to 60,000 tooth brushing cycles with dentifrices containing up to 5,000 μg/g of F-.

Download full-text PDF

Source
http://dx.doi.org/10.11607/ijp.7187DOI Listing

Publication Analysis

Top Keywords

tooth brushing
24
brushing cycles
20
Δe00 Δt00
16
60000 tooth
12
dentifrice fluoride
8
fluoride concentration
8
glazed cad/cam
8
5000 μg/g
8
subjected 60000
8
Δt00 values
8

Similar Publications