Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Physical activity is increasingly being captured by accelerometers worn on different body locations. The aim of this study was to examine the associations between physical activity volume (average acceleration), intensity (intensity gradient) and cardiometabolic health when assessed by a thigh-worn and wrist-worn accelerometer. A sample of 659 office workers wore an Axivity AX3 on the non-dominant wrist and an activPAL3 micro on the right thigh concurrently for 24 h a day for 8 days. An average acceleration (proxy for physical activity volume) and intensity gradient (intensity distribution) were calculated from both devices using the open-source raw accelerometer processing software GGIR. Clustered cardiometabolic risk (CMR) was calculated using markers of cardiometabolic health, including waist circumference, triglycerides, HDL-cholesterol, mean arterial pressure and fasting glucose. Linear regression analysis assessed the associations between physical activity volume and intensity gradient with cardiometabolic health. Physical activity volume derived from the thigh-worn activPAL and the wrist-worn Axivity were beneficially associated with CMR and the majority of individual health markers, but associations only remained significant after adjusting for physical activity intensity in the thigh-worn activPAL. Physical activity intensity was associated with CMR score and individual health markers when derived from the wrist-worn Axivity, and these associations were independent of volume. Associations between cardiometabolic health and physical activity volume were similarly captured by the thigh-worn activPAL and the wrist-worn Axivity. However, only the wrist-worn Axivity captured aspects of the intensity distribution associated with cardiometabolic health. This may relate to the reduced range of accelerations detected by the thigh-worn activPAL.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10489920PMC
http://dx.doi.org/10.3390/s23177353DOI Listing

Publication Analysis

Top Keywords

physical activity
36
cardiometabolic health
24
activity volume
20
thigh-worn activpal
16
wrist-worn axivity
16
health physical
12
intensity gradient
12
physical
9
associations cardiometabolic
8
health
8

Similar Publications

Background: Gait impairment in Parkinson's disease (PD) occurs early and pharmaceutical interventions do not fully restore this function. Visual cueing has been shown to improve gait and alleviate freezing of gait (FOG) in PD. Technological development of digital laser shoe visual cues now allows for visual cues to be used continuously when walking.

View Article and Find Full Text PDF

The adverse effects of Western diets (WD), high in both fat and simple sugars, which contribute to obesity and related disorders, have been extensively studied in laboratory rodents, but not in non-laboratory animals, which limits the scope of conclusions. Unlike laboratory mice or rats, non-laboratory rodents that reduce body mass for winter do not become obese when fed a high-fat diet. However, it is not known whether these rodents are also resistant to the adverse effects of WD.

View Article and Find Full Text PDF

There is a concern on the safety of cosmetic ingredients and their endocrine-disrupting (ED) potential. Frequent use as well as the use of a diverse range of cosmetics pose a concern for a potential health risk via aggregate exposure to endocrine disrupting chemicals (EDCs). In this study, a list of ingredients available in cosmetic products that were recently introduced to the Dutch market was retrieved from the commercially accessible Mintel database and screened for the presence of EDCs.

View Article and Find Full Text PDF

Mechanically Heterogeneous Architecture Enables Robust and Ultrathin Bioelectronics for High-Fidelity Biosignal Monitoring.

ACS Sens

September 2025

State Key Laboratory of Advanced Fiber Materials, College of Materials Science and Engineering, Donghua University, Shanghai 201620, China.

High-fidelity biosignal monitoring is essential for daily health tracking and the diagnosis of chronic diseases. However, developing bioelectrodes capable of withstanding repeated use and mechanical deformation on wet tissue surfaces remains a significant challenge. Here, we present a robust and ultrathin bioelectrode (RUB), featuring a mechanically heterogeneous architecture and a thickness of ∼3 μm.

View Article and Find Full Text PDF

The purpose of this study was to evaluate the evolution of jump and sprint force-production capacities with maturation in young soccer players. One hundred sixteen young elite male soccer players aged 11-17 years were assigned to six different groups according to their maturity status. The force-velocity (F-V) profiles in jumping and sprinting performances were compared among groups.

View Article and Find Full Text PDF