A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Changes in Parameters after High Tibial Osteotomy: Comparison of EOS System and Computed Tomographic Analysis. | LitMetric

Changes in Parameters after High Tibial Osteotomy: Comparison of EOS System and Computed Tomographic Analysis.

J Clin Med

Department of Orthopedic Surgery, College of Medicine, Konyang University, 158 Gwanjeodong-ro, Seo-gu, Daejeon 35365, Republic of Korea.

Published: August 2023


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Unintended rotation of the distal tibia occurs during medial open-wedge high tibial osteotomy (MOWHTO). Computed tomography (CT) is the standard method of measuring lower limb alignment; however, the new low-dose EOS system allows three-dimensional limb modeling with automated measurements of lower limb alignment. This study investigated the differences between the changes in lower limb alignment profiles obtained using the EOS system and CT in patients who underwent MOWHTO. We investigated whether any factors contributed to the degree of deformation. Thirty patients were prospectively enrolled between October 2019 and February 2023. Changes in femoral and tibial torsion, femorotibial rotation, and posterior tibial slope were measured using pre- and post-MOWHTO CT and EOS images. We found no significant difference in pre- and postoperative tibial torsion or posterior tibial slope between CT and EOS. No variables showed a significant correlation with changes in the tibial torsion or posterior tibial slope. This study confirmed the possibility that the EOS system could replace CT in measuring changes in several parameters pre- and postoperatively. Furthermore, we confirmed that the distal tibia tended to be internally rotated after MOWHTO; however, we found no significantly related parameters related to deformation caused by MOWHTO.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10488862PMC
http://dx.doi.org/10.3390/jcm12175638DOI Listing

Publication Analysis

Top Keywords

eos system
16
lower limb
12
limb alignment
12
tibial torsion
12
posterior tibial
12
tibial slope
12
changes parameters
8
tibial
8
high tibial
8
tibial osteotomy
8

Similar Publications