A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Challenges of reliable AFM-tip shape reconstruction and approximation. | LitMetric

Challenges of reliable AFM-tip shape reconstruction and approximation.

Microsc Res Tech

Department of Micromechanics of Media with Inhomogeneous Structure, Institute of Continuous Media Mechanics UB RAS, Perm, Russia.

Published: January 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Reliable reconstruction of AFM tip geometry is not an easy task. The shape of the tip can be (partially) reconstructed from the AFM image of a calibration sample using a blind reconstruction method. The result is a range of the tip shapes (from unrealistically sharp to blunt). A criterion for selecting the true shape is proposed. It is based on reconstruction of the calibration relief. Further refining the probe geometry by indenting an elastic polymer is discussed. The choice of the test sample is another problem. In practice, the researcher has a small number of commercially available test gratings. Their limitations are highlighted. An approximation of tip geometry by a body of revolution is required in indentation experiments. A hyperboloid was found to be the closest approximation to the conventional probes. The contact area was obtained for the hyperboloids with different parameters indenting an elastic material. RESEARCH HIGHLIGHTS: Criteria for blind reconstruction algorithm of AFM tip shape. Pros and cons of tip shape calibration samples. Contact area of the elastic indentation by hyperbolic indenter.

Download full-text PDF

Source
http://dx.doi.org/10.1002/jemt.24415DOI Listing

Publication Analysis

Top Keywords

blind reconstruction
8
indenting elastic
8
contact area
8
shape
5
reconstruction
5
challenges reliable
4
reliable afm-tip
4
afm-tip shape
4
shape reconstruction
4
reconstruction approximation
4

Similar Publications