Continuous glucose monitors (CGMs) have transformed the way people with type 1 diabetes can self-monitor glucose levels. Past studies have evaluated the accuracy of CGMs in clinic-based studies, but few have analyzed their accuracy in real-world settings. The Insulin-Only Bionic Pancreas Trial provided the opportunity to assess real-world accuracy of the blinded Dexcom G6 Pro sensor over the first 48-60 h of wear using a blood glucose meter (BGM) as a comparator for 1073 CGM-BGM pairs across 53 participants. The mean absolute relative difference (MARD) was 11.0% over a median period of 50 h (range 47-79 h). The MARD was 13.6% in the first 12 h, 10.5% in hours 12-24, and 10.1% after the first 24 h. These results are comparable with accuracy shown previously with laboratory-based measurements and provide real-world evidence of Dexcom G6 Pro accuracy, which improved after the first 12 h and then remained stable thereafter. Clinical Trial Registry: clinicaltrials.gov; NCT04200313.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10771867 | PMC |
http://dx.doi.org/10.1089/dia.2023.0287 | DOI Listing |
Diabetes Technol Ther
August 2025
Division of Metabolism, Endocrinology, and Nutrition, University of Washington, Seattle, Washington, USA.
Continuous glucose monitors (CGMs) can comprehensively assess glycemic patterns in patients treated with dialysis, in whom conventional biomarkers such as glycated hemoglobin are inaccurate. Nonetheless, adoption of recent versions of CGMs in this population has been complicated by concerns about interstitial volume expansion, interfering substances, and effects of dialysis treatment. This study aimed to examine the accuracy of the G6 Pro and G7 CGM systems (Dexcom, Inc.
View Article and Find Full Text PDFDiabetes Technol Ther
August 2025
Center for Diabetes and Endocrinology, University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA.
To evaluate the accuracy of the Dexcom G6 Pro continuous glucose monitoring (CGM) system in the intensive care unit (ICU) setting. We performed a prospective, observational, multicenter study in adult ICU patients with a known diagnosis of diabetes or stress hyperglycemia who were being treated with insulin. Two Dexcom G6 Pro sensors were placed.
View Article and Find Full Text PDFJ Med Internet Res
June 2025
Roche Diabetes Care GmbH, Mannheim, Germany.
Background: The treatment of diabetes requires substantial self-management. Digital tools can help reduce the burden of self-management and may improve glycemic control.
Objective: This study aims to determine whether the use of a digital diabetes logbook increased the likelihood of achieving optimal glycemic control (glycated hemoglobin [HbA] ≤6.
JACC Adv
June 2025
Saint Luke's Mid America Heart Institute, Kansas City, Missouri, USA; University of Missouri-Kansas City School of Medicine, Kansas City, Missouri, USA. Electronic address:
Background: Apolipoprotein M (ApoM) is associated with lower mortality in heart failure (HF) patients and protects against cardiac and kidney injury in mice.
Objectives: The authors investigated dapagliflozin's cardiorenal effects by studying its association with ApoM in patients with HF with reduced ejection fraction.
Methods: We performed a secondary analysis of DEFINE-HF (Dapagliflozin Effects on Biomarkers, Symptoms, and Functional Status in Patients with HF with Reduced Ejection Fraction) to assess dapagliflozin's effects on ApoM, N-terminal pro B-type natriuretic peptide (NT-proBNP), and urine albumin-creatinine ratio (UACR) changes from baseline to 12 weeks.
Diabetes Technol Ther
June 2025
Diabetes Research Center, Massachusetts General Hospital, Boston, Massachusetts, USA.
We investigated the association between continuous glucose monitoring (CGM) metrics and clinical outcomes in the nonintensive care unit (non-ICU) setting. In this observational cohort study, patients on non-ICU floors wore blinded Dexcom G6 Pro CGM. CGM metrics and occurrence of CGM-detected severe hypoglycemia were measured.
View Article and Find Full Text PDF