Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: The aim of the present study is to evaluate the possible advantages of the Robo-Lap (parenchymal transection by laparoscopic ultrasonic dissector and robotic bipolar forceps and scissors) compared with pure robotic technique (parenchymal transection by use of robotic bipolar forceps and scissors) in major anatomical liver resections with specific focus on intraoperative outcomes.

Methods: Major liver resections performed by robotic approach between February 1, 2021 and March 31, 2023 were stratified into two groups according to the approach used to address the phase of liver transection; Pure Robotic Group (n = 21) versus Robo-Lap Group (n = 48). The two groups were compared in terms of intra- and postoperative outcomes and in terms of rate of achievement of intraoperative textbook outcomes.

Results: Conversion rate was similar between the two groups while incidence of adverse intraoperative events (according to Satava classification) was higher in the Pure Robotic compared with the Robo-Lap group (85.7% vs 39.6%, p < 0.001). Time to perform parenchymal transection was significantly shorter in the Robo-Lap group (180 min) compared with the Pure Robotic Group (240 min), p = 0.003. Intraoperative textbook outcomes were achieved in a lower proportion of patients in the Pure Robotic compared with the Robo-Lap group.

Conclusion: Outcomes of the present study suggest a favorable role of the Robo-Lap approach in robotic major resections as it allows an improvement of the intraoperative results, a greater probability of an uneventful conduction of the procedure, and therefore, better management of the operating room time.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC10473182PMC
http://dx.doi.org/10.4293/JSLS.2023.00025DOI Listing

Publication Analysis

Top Keywords

pure robotic
20
parenchymal transection
12
robo-lap group
12
robotic
10
robo-lap approach
8
robotic bipolar
8
bipolar forceps
8
forceps scissors
8
compared pure
8
liver resections
8

Similar Publications

Robots can benefit from touch perception for enhanced interaction. Interaction involves tactile sensing devices, contact objects, and complex directional force motions (normal and shear) in between. We introduce a comprehensive theory unifying them to advance sensor design, explain shear-induced performance drops, and suggest application scenarios.

View Article and Find Full Text PDF

Simple method for the production of rete ridges in human dermo-epidermal skin substitutes.

Exp Cell Res

August 2025

Tissue Biology Research Unit, Department of Pediatric Surgery, University Children's Hospital Zurich, University of Zurich, Zurich, Switzerland; Department of Pediatric Surgery, University Children's Hospital Zurich, University of Zurich, Zurich, Switzerland; Zurich Center for Fetal Diagnosis and Tr

The engineering of autologous dermo-epidermal skin substitutes aims to replicate the functional and structural properties of normal human skin for treating severe burns, trauma, congenital giant nevi, and necrosis-inducing diseases. We established autologous dermo-epidermal skin analogues, the quality of which is presently being assessed in phase II and III trials. A primary challenge we are facing involves the incorporation of undulating epidermal extensions, known as rete ridges, into the dermis.

View Article and Find Full Text PDF

Background: The utilization of robot-assisted laparoscopic pyeloplasty (RALP) for the surgical correction of ureteropelvic junction obstruction (UPJO) continues to increase. The aim of this study was to determine whether robot-assisted laparoscopic pyeloplasty (RALP) is a safe and equally efficacious procedure compared to open pyeloplasty (OP) in infants ≤12 months old.

Methods: All patients ≤12 months old who underwent RALP or OP between January 2012 and January 2021 at five participating centers were included in this study.

View Article and Find Full Text PDF

Purpose: We aimed to investigate the optimal port placement for robot-assisted radical nephroureterectomy (RANU) using the hinotori surgical robot system (HSRS), by considering the distance between ports and the number of interferences between the robotic arms.

Methods: We retrospectively included seven consecutive patients undergoing RANU using HSRS between March and July of 2023. The distances between ports and the number of interferences between the robotic arms were analyzed from the log data.

View Article and Find Full Text PDF

Piezoelectricity, the generation of an electric charge in response to mechanical stress, is a key property in both natural and synthetic materials. This study significantly boosts the piezoelectric response of chitosan, a biodegradable biopolymer, by integrating chitin/surface-deacetylated chitin nanocrystals into natural chitosan-based thin films. The resulting materials, produced in our laboratories, achieve values of up to 18.

View Article and Find Full Text PDF